Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2002 Jul;56(1):95-9.
doi: 10.1067/mge.2002.125362.

Efficacy of colonic submucosal saline solution injection for the reduction of iatrogenic thermal injury

Affiliations

Efficacy of colonic submucosal saline solution injection for the reduction of iatrogenic thermal injury

Ian D Norton et al. Gastrointest Endosc. 2002 Jul.

Abstract

Background: Submucosal saline solution injection may limit the depth of thermal injury to the gut wall by acting as a heat-sink and by increasing the distance between burn and serosa. The aim of this study was to determine the effect of submucosal saline solution injection on depth of colonic thermal injury produced by commonly used endoscopic thermal modalities.

Methods: Longitudinal colotomy incisions were made on the antimesenteric colonic border of anesthetized swine. Lesions were made by using a bipolar device (20 W, 2 seconds), heat probe (30 J); monopolar contact with hot biopsy forceps (20 W, 2 seconds), and monopolar noncontact with argon plasma coagulation (45 W, 3 seconds). Ten or more lesions were created with each device. Lesions were made with or without prior submucosal injection of 2 mL of normal saline solution. After 24 hours the lesions were excised for histologic analysis. Injury was assessed in relation to the severity of damage to the deep (longitudinal) muscle layer.

Results: The proportions of control lesions (without submucosal saline solution injection) in which deep injury was evident were as follows: argon plasma coagulation, 86%; hot biopsy forceps, 64%; heat probe, 50%; bipolar device, 18%. Submucosal saline solution injection significantly reduced the proportions of lesions with deep injury for argon plasma coagulation (p = 0.009) and heat probe (p = 0.03), but not hot biopsy forceps or bipolar device (argon plasma coagulation, 86% to 21%; heat probe, 50% to 0%; hot biopsy forceps, 64% to 50%; bipolar device, 18% to 9%).

Conclusions: At equivalent energy outputs, the bipolar device results in less deep injury than the monopolar or heat probe. Submucosal saline solution injection reduced injury to the muscularis propria caused by both heat probe and argon plasma coagulation, but not hot biopsy forceps. Despite submucosal saline solution injection, caution should be exercised when using prolonged monopolar cautery.

PubMed Disclaimer

Publication types

Substances

LinkOut - more resources