Fluid and solid mechanical implications of vascular stenting
- PMID: 12086001
- DOI: 10.1114/1.1458594
Fluid and solid mechanical implications of vascular stenting
Abstract
Vascular stents have emerged as an effective treatment for occlusive vascular disease. Despite their success and widespread use, outcomes for patients receiving stents are still hampered by thrombosis and restensosis. As arteries attempt to adapt to the mechanical changes created by stents, they may in fact create a new flow-limiting situation similar to that which they were intended to correct. In vitro fluid mechanics and solid mechanics studies of stented vessels have revealed important information about how stents alter the mechanical environment in the arteries into which they are placed. Adverse nonlaminar flow patterns have been demonstrated as well as remarkably high stress concentrations in the vessel wall. In vivo studies of stented vessels have also shown a strong relationship between stent design and their dynamic performance within arteries. Alterations in pressure and flow pulses distal to the stent have been observed, as well as regional changes in vascular compliance. Considering the influence of flow and stress on the vascular response and the suboptimal clinical outcomes associated with stenting, knowledge gained from stent/artery mechanics studies should play an increasingly important role in improving the long-term patency of these devices.
Similar articles
-
Circumferential vascular deformation after stent implantation alters wall shear stress evaluated with time-dependent 3D computational fluid dynamics models.J Appl Physiol (1985). 2005 Mar;98(3):947-57. doi: 10.1152/japplphysiol.00872.2004. Epub 2004 Nov 5. J Appl Physiol (1985). 2005. PMID: 15531564
-
The role of vessel geometry and material properties on the mechanics of stenting in the coronary and peripheral arteries.Proc Inst Mech Eng H. 2010;224(3):465-76. doi: 10.1243/09544119JEIM695. Proc Inst Mech Eng H. 2010. PMID: 20408491
-
Blood flow in stented arteries: a parametric comparison of strut design patterns in three dimensions.J Biomech Eng. 2005 Aug;127(4):637-47. doi: 10.1115/1.1934122. J Biomech Eng. 2005. PMID: 16121534
-
Computational fluid dynamics and stent design.Artif Organs. 2002 Jul;26(7):614-21. doi: 10.1046/j.1525-1594.2002.07084.x. Artif Organs. 2002. PMID: 12081520 Review.
-
Blood vessel constitutive models-1995-2002.Annu Rev Biomed Eng. 2003;5:413-39. doi: 10.1146/annurev.bioeng.5.011303.120719. Epub 2003 Apr 18. Annu Rev Biomed Eng. 2003. PMID: 12730083 Review.
Cited by
-
Endovascular stent-induced alterations in host artery mechanical environments and their roles in stent restenosis and late thrombosis.Regen Biomater. 2018 Jun;5(3):177-187. doi: 10.1093/rb/rby006. Epub 2018 May 2. Regen Biomater. 2018. PMID: 29942650 Free PMC article. Review.
-
Comparison of in vitro human endothelial cell response to self-expanding stent deployment in a straight and curved peripheral artery simulator.J R Soc Interface. 2013 Jan 30;10(81):20120965. doi: 10.1098/rsif.2012.0965. Print 2013 Apr 6. J R Soc Interface. 2013. PMID: 23365191 Free PMC article.
-
Modeling of Soft Tissues Interacting with Fluid (Blood or Air) Using the Immersed Finite Element Method.J Biomed Sci Eng. 2014 Feb;7(3):130-145. doi: 10.4236/jbise.2014.73018. J Biomed Sci Eng. 2014. PMID: 26855688 Free PMC article.
-
Vascular injury post stent implantation: different gene expression modulation in human umbilical vein endothelial cells (HUVECs) model.PLoS One. 2014 Feb 26;9(2):e90213. doi: 10.1371/journal.pone.0090213. eCollection 2014. PLoS One. 2014. PMID: 24587287 Free PMC article.
-
Constraining OCT with Knowledge of Device Design Enables High Accuracy Hemodynamic Assessment of Endovascular Implants.PLoS One. 2016 Feb 23;11(2):e0149178. doi: 10.1371/journal.pone.0149178. eCollection 2016. PLoS One. 2016. PMID: 26906566 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Research Materials