Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2002 Jul;137(7):813-7.
doi: 10.1001/archsurg.137.7.813.

Effect of topically applied charged particles on healing of colonic anastomoses

Affiliations

Effect of topically applied charged particles on healing of colonic anastomoses

Mehmet Guler et al. Arch Surg. 2002 Jul.

Abstract

Hypothesis: Various forms of electrical stimulation can improve wound healing in different tissues, but their application to gastrointestinal tract healing has not been investigated. We assumed that positively charged diethylaminoethyl cross-linked dextran bead (diethylaminoethyl Sephadex [DEAE-S]) particles would have a beneficial effect on the healing of colonic anastomoses.

Design: Experimental animal study.

Setting: Animal research laboratory of a university hospital.

Animals: Forty female Wistar albino rats.

Interventions: Right colonic transection and anastomosis was performed in 5 animal groups. The control group received no treatment; the placebo group, methylcellulose gel; and the DEAE-S group, DEAE-S in methyl cellulose gel applied topically around the anastomoses. The fecal peritonitis (FP) group underwent cecal ligation and perforation simultaneously with the anastomosis to cause FP; the FP + DEAE-S group also received DEAE-S applied around the anastomoses.

Main outcome measures: After the completion of postoperative day 4, all rats were killed. Anastomotic bursting pressures and hydroxyproline concentrations in perianastomotic tissue were measured and compared.

Results: Mean bursting pressures were 115.1 mm Hg in the control group, 113.6 mm Hg in the placebo group, 159.4 mm Hg in the DEAE-S group, 62.8 mm Hg in the FP group, and 121.1 mm Hg in the FP + DEAE-S group (P =.001, 1-way analysis of variance [ANOVA]). The differences between the control vs DEAE-S groups, placebo vs DEAE-S groups, and FP vs FP + DEAE-S groups were significant (P<.05, t test). Mean hydroxyproline concentrations were 5.2 microg/mg in the control group, 4.9 microg/mg in the placebo group, 5.6 microg/mg in the DEAE-S group, 4.5 microg/mg in the FP group, and 5.4 microg/mg in the FP + DEAE-S group (P =.09, 1-way ANOVA). The difference between the FP and FP + DEAE-S groups was significant (P =.04, t test).

Conclusions: A positively charged particle, DEAE-S, improves healing of colonic anastomoses in healthy rats and in rats with FP. This inexpensive, nontoxic material is easily applied and deserves further evaluation in gastrointestinal tract healing.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources