Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2002 Jul 31;29(5):939-45.
doi: 10.1016/s0731-7085(02)00167-x.

A simple LC method with UV detection for the analysis of creatine and creatinine and its application to several creatine formulations

Affiliations

A simple LC method with UV detection for the analysis of creatine and creatinine and its application to several creatine formulations

Alekha K Dash et al. J Pharm Biomed Anal. .

Abstract

The objective of this study was to develop a simple and sensitive LC method for the determination of creatine and creatinine in various creatine supplement formulations. The chromatographic system comprised of a LC-600 pump, SCL-6B system controller, and SPD-6AV detector (Shimadzu, Japan). The mobile phase consisted of 0.045 M ammonium sulfate in water. The chromatographic separation was achieved at ambient temperature on a Betabasic C-18 column (250 x 4.6 mm, Keystone Sci.). The flow rate was maintained at 0.75 ml/min and effluents are monitored at 205 nm. 4-(2-Aminoethyl)benzene sulfonamide was used as an internal standard (IS). This method required less than 7 min of chromatographic time. The standard curves were linear over the concentration range of 1-100 microg/ml for creatine and 2-100 microg/ml for creatinine, respectively. The relative standard deviations (RSD) for the within-day and day-to-day precision for creatine were within 1.0-4.6 and 2.2-4.7%, respectively. The RSD for the accuracy of creatine assay was in the range of 2.4-4.7%. The RSD values for the within-day precision, day-to-day precision and accuracy for creatinine validation were 1.7-4.4, 2.3-5.4 and 2.4-4.8%, respectively. This method was used to determine: (i) the creatine concentration in various marketed products; (ii) saturated solubility of various creatine salts; and (iii) stability of creatine in aqueous solution. In conclusion, a simple and sensitive LC method with UV detection was developed for the simultaneous determination of creatine and creatinine in formulations. Di-creatine citrate salt showed a higher aqueous solubility (at 25 degrees C) as compared to creatine and creatine monohydrate. Some of the over-the-counter (OTC) products tested contained a very low level of creatine in contrast to their label claim. Substantial conversion of creatine into creatinine was noticed in liquid formulation.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources