Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2002 May;26(5):592-7.
doi: 10.1007/s00268-001-0274-2. Epub 2002 Mar 1.

Comparison of vital dye-guided lymphatic mapping and dye plus gamma probe-guided sentinel node biopsy in breast cancer

Affiliations
Comparative Study

Comparison of vital dye-guided lymphatic mapping and dye plus gamma probe-guided sentinel node biopsy in breast cancer

Gábor Cserni et al. World J Surg. 2002 May.

Abstract

The optimal technique for sentinel lymph node biopsy (SLNB) is still debated. SLNB with peritumoral injection of Patent blue dye was performed in 129 clinically T1-T2 and N0 breast cancers in 127 patients (group A); it was later replaced by combined dye and radiocolloid-guided SLNB preceded by lymphoscintigraphy in 72 breast cancer patients (group B). This study compares these two methods. All patients underwent completion axillary dissection. Means of 1.4 and 1.3 SLNs were identified in groups A and B, respectively. The mean number of non-SLNs for the whole series was 14.9 (range 5-42). The first 53 cases of lymphatic mapping (dye only) comprised the institutional learning period during which the identification rate of at least 1 SLN in 30 consecutive attempts reached 90%. The identification rate for the subsequent 76 group A patients was 92%. The accuracy rate of SLNBs for overall axillary nodal status prediction and the false-negative rate for group A patients (after excluding the learning-phase cases) were 93% and 10%, respectively. All 72 group B cases had at least one SLN identified, and only one false-negative case occurred in this group (accuracy and false-negative rates of 99% and 3%, respectively). Both the dye-only and the combined SLNB methods are suitable for SLN identification, but the latter works better and results in higher accuracy, a higher negative predictive value, and a lower false-negative rate. It is therefore the method of choice.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Ann Surg. 2000 Jul;232(1):81-9 - PubMed
    1. Br J Surg. 2000 Jul;87(7):920-5 - PubMed
    1. Eur J Surg Oncol. 1998 Apr;24(2):93-5 - PubMed
    1. Cancer. 2000 Jun 1;88(11):2546-52 - PubMed
    1. Med J Aust. 1999 Nov 1;171(9):461-5 - PubMed

Publication types

Substances

LinkOut - more resources