Reproducibility of total cerebral blood flow measurements using phase contrast magnetic resonance imaging
- PMID: 12112496
- DOI: 10.1002/jmri.10133
Reproducibility of total cerebral blood flow measurements using phase contrast magnetic resonance imaging
Abstract
Purpose: To evaluate reproducibility of total cerebral blood flow (CBF) measurements with phase contrast magnetic resonance imaging (pcMRI).
Materials and methods: We repeated total CBF measurements in 15 healthy volunteers with and without cardiac triggering, and with and without repositioning. In eight volunteers measurements were performed at two different occasions. In addition, measurement of flow in a phantom was performed to validate MR measurements.
Results: A difference of 40.4 ml/minute was found between CBF measurements performed with and without triggering (P < 0.05). For repeated triggered measurements, the coefficient of variation (CV) was 7.1%, and for nontriggered measurements 10.3%. For repeated measurements with repositioning, the CV was 7.1% with and 11.2% without triggering. Repeated measurements at different occasions showed a CV of 8.8%. Comparing measured with real flow in the phantom, the triggered differed 4.9% and the nontriggered 8.3%.
Conclusion: The findings of this study demonstrate that pcMRI is a reliable method to measure total CBF in terms of both accuracy and reproducibility.
Copyright 2002 Wiley-Liss, Inc.
Similar articles
-
Renal blood flow measurements with use of phase-contrast magnetic resonance imaging: normal values and reproducibility.J Vasc Interv Radiol. 2005 Jun;16(6):807-14. doi: 10.1097/01.RVI.0000161144.98350.28. J Vasc Interv Radiol. 2005. PMID: 15947044
-
Automatic model-based contour detection and blood flow quantification in small vessels with velocity encoded magnetic resonance imaging.Invest Radiol. 2003 Sep;38(9):567-77. doi: 10.1097/01.RLI.0000077125.58014.36. Invest Radiol. 2003. PMID: 12960526
-
Effect of flip angle on volume flow measurement with nontriggered phase-contrast MR: In vivo evaluation in carotid and basilar arteries.J Magn Reson Imaging. 2009 May;29(5):1218-23. doi: 10.1002/jmri.21748. J Magn Reson Imaging. 2009. PMID: 19388100
-
Effect of age on cerebral blood flow: measurement with ungated two-dimensional phase-contrast MR angiography in 250 adults.Radiology. 1998 Dec;209(3):667-74. doi: 10.1148/radiology.209.3.9844657. Radiology. 1998. PMID: 9844657 Review.
-
Flow quantification extends MRA's neuro applications.Diagn Imaging (San Franc). 1993 May;15(5):68-77. Diagn Imaging (San Franc). 1993. PMID: 10148579 Review. No abstract available.
Cited by
-
Kidney Function and Cerebral Blood Flow: The Rotterdam Study.J Am Soc Nephrol. 2016 Mar;27(3):715-21. doi: 10.1681/ASN.2014111118. Epub 2015 Aug 6. J Am Soc Nephrol. 2016. PMID: 26251352 Free PMC article.
-
MRI evaluation of cerebrovascular reactivity in obstructive sleep apnea.J Cereb Blood Flow Metab. 2020 Jun;40(6):1328-1337. doi: 10.1177/0271678X19862182. Epub 2019 Jul 15. J Cereb Blood Flow Metab. 2020. PMID: 31307289 Free PMC article.
-
Reduced parenchymal cerebral blood flow is associated with greater progression of brain atrophy: The SMART-MR study.J Cereb Blood Flow Metab. 2021 Jun;41(6):1229-1239. doi: 10.1177/0271678X20948614. Epub 2020 Aug 17. J Cereb Blood Flow Metab. 2021. PMID: 32807000 Free PMC article.
-
MR derived volumetric flow rate waveforms of internal carotid artery in patients treated for unruptured intracranial aneurysms by flow diversion technique.J Cereb Blood Flow Metab. 2015 Dec;35(12):2070-9. doi: 10.1038/jcbfm.2015.176. Epub 2015 Aug 12. J Cereb Blood Flow Metab. 2015. PMID: 26264871 Free PMC article.
-
High total cerebral blood flow is associated with a decrease of white matter lesions.J Neurol. 2004 Dec;251(12):1481-5. doi: 10.1007/s00415-004-0569-y. J Neurol. 2004. PMID: 15645347
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical