The application accuracy of the NeuroMate robot--A quantitative comparison with frameless and frame-based surgical localization systems
- PMID: 12112718
- DOI: 10.1002/igs.10035
The application accuracy of the NeuroMate robot--A quantitative comparison with frameless and frame-based surgical localization systems
Abstract
The NeuroMatetrade mark robot system (Integrated Surgical Systems, Davis, CA) is a commercially available, image-guided, robotic-assisted system used for stereotactic procedures in neurosurgery. In this article, we present a quantitative comparison of the application accuracy of the NeuroMate with that of standard frame-based and frameless stereotactic techniques. The article discusses a five-way application accuracy comparison study. The variables of our comparison and their mean errors are as follows: (1) with the robot in a frame-based configuration, the RMS was 0.86 +/- 0.32 mm; (2) with the robot in the frameless configuration, the RMS was 1.95 +/- 0.44 mm; (3) in a standard stereotactic (ZD) frame-based approach, the RMS was 1.17 +/- 0.25 mm; (4) with an infrared tracking system using the frame for fiducial registration, the RMS was 1.47 +/- 0.45 mm; (5) with an infrared tracking system using screw markers for registration, the RMS was 0.68 +/- 0.26 mm. The study was performed with 2-mm sections of CT scans. These results show that the application accuracy of the frame-based NeuroMate robot is comparable to that of standard localizing systems, whether they are frame-based or infrared tracked.
Copyright 2002 Wiley-Liss, Inc.
Similar articles
-
Validation of the PathFinder neurosurgical robot using a phantom.Int J Med Robot. 2007 Dec;3(4):372-7. doi: 10.1002/rcs.153. Int J Med Robot. 2007. PMID: 17914750
-
Use of the NeuroMate stereotactic robot in a frameless mode for functional neurosurgery.Int J Med Robot. 2006 Jun;2(2):107-13. doi: 10.1002/rcs.88. Int J Med Robot. 2006. PMID: 17520621
-
Application accuracy study of a semipermanent fiducial system for frameless stereotaxis.Comput Aided Surg. 1997;2(5):257-63. doi: 10.1002/(SICI)1097-0150(1997)2:5<257::AID-IGS1>3.0.CO;2-Z. Comput Aided Surg. 1997. PMID: 9484586
-
Techniques for Stereotactic Neurosurgery: Beyond the Frame, Toward the Intraoperative Magnetic Resonance Imaging-Guided and Robot-Assisted Approaches.World Neurosurg. 2018 Aug;116:77-87. doi: 10.1016/j.wneu.2018.04.155. Epub 2018 May 3. World Neurosurg. 2018. PMID: 29730102 Review.
-
Devices for targeting the needle.Neurosurg Clin N Am. 2009 Apr;20(2):187-91. doi: 10.1016/j.nec.2009.04.006. Neurosurg Clin N Am. 2009. PMID: 19555881 Review.
Cited by
-
Insights into Infusion-Based Targeted Drug Delivery in the Brain: Perspectives, Challenges and Opportunities.Int J Mol Sci. 2022 Mar 15;23(6):3139. doi: 10.3390/ijms23063139. Int J Mol Sci. 2022. PMID: 35328558 Free PMC article. Review.
-
An Integrated Robotic System for MRI-Guided Neuroablation: Preclinical Evaluation.IEEE Trans Biomed Eng. 2020 Oct;67(10):2990-2999. doi: 10.1109/TBME.2020.2974583. Epub 2020 Feb 17. IEEE Trans Biomed Eng. 2020. PMID: 32078530 Free PMC article.
-
Safety and efficacy of frameless stereotactic robot-assisted intraparenchymal brain lesion biopsies versus image-guided biopsies: a bicentric comparative study.Acta Neurochir (Wien). 2024 Feb 6;166(1):67. doi: 10.1007/s00701-024-05912-7. Acta Neurochir (Wien). 2024. PMID: 38319393
-
Equipment and technology in surgical robotics.World J Urol. 2006 Jun;24(2):128-35. doi: 10.1007/s00345-006-0070-6. Epub 2006 Mar 15. World J Urol. 2006. PMID: 16538515 Review.
-
An integrated system for planning, navigation and robotic assistance for skull base surgery.Int J Med Robot. 2008 Dec;4(4):321-30. doi: 10.1002/rcs.213. Int J Med Robot. 2008. PMID: 18803337 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources