Comparison of the clinical performance of Healon 5 and Healon in phacoemulsification
- PMID: 12113566
- DOI: 10.1177/112067210201200306
Comparison of the clinical performance of Healon 5 and Healon in phacoemulsification
Abstract
Purpose: Healon 5 is a high-molecular-mass fraction of sodium hyaluronate. Its density endows it with a number of viscoelastic characteristics. In this prospective, randomised clinical study we compared the performance of Healon 5 and Healon in phacoemulsification.
Setting: Institute of Ophthalmology, University of Modena and Reggio Emilia, Italy.
Methods: Two groups of patients underwent phacoemulsification and intraocular lens (IOL) implantation. In the first 27 patients Healon 5 was used as viscoelastic substance during surgery, and in the second 27 Healon was used. The surgeons subjective comments on the performance of these viscoelastic agents were recorded at the different steps of surgery: injection, capsulorhexis, phacoemulsification, IOL implantation, removal of viscoelastic agent and trasparency throughout the operation. The surgeon's overall impression of the viscoelastics during the whole operation was noted. Tonometry and endothelial cell count were performed in all patients before and after operation.
Results: There was no statistical difference between the two groups as regards visual acuity, ocular pressure and endothelial damage. Healon 5 showed excellent ability to maintain the anterior chamber during capsulorhexis, phacoemulsification and IOL implantation. Removal time with Healon 5 was not appreciably longer than Healon.
Conclusions: Healon 5 emerges as a very interesting viscoelastic substance. Visibility is better if the anterior chamber is filled completely. Removal is easier if it is aspirated while moving the irrigation aspiration tip with circular movements over the top and around the border of the IOL.
Similar articles
-
Clinical comparison of Healon5 and Healon in phacoemulsification and intraocular lens implantation; Randomized multicenter study.J Cataract Refract Surg. 2004 Feb;30(2):357-62. doi: 10.1016/S0886-3350(03)00615-1. J Cataract Refract Surg. 2004. PMID: 15030824 Clinical Trial.
-
Randomized clinical comparison of Healon GV and Viscoat.J Cataract Refract Surg. 1999 Dec;25(12):1630-6. doi: 10.1016/s0886-3350(99)00244-8. J Cataract Refract Surg. 1999. PMID: 10609208 Clinical Trial.
-
The clinical study of Healon 5 in phacoemulsification and IOL implantation.Yan Ke Xue Bao. 2001 Sep;17(3):186-90. Yan Ke Xue Bao. 2001. PMID: 12567750 Clinical Trial.
-
[Prospective randomized trial comparing Discovisc versus Healon in phacoemulsification].Arch Soc Esp Oftalmol. 2007 Aug;82(8):489-94. doi: 10.4321/s0365-66912007000800007. Arch Soc Esp Oftalmol. 2007. PMID: 17717768 Clinical Trial. Spanish.
-
Physical Characteristics, Clinical Application, and Side Effects of Viscoelastics in Ophthalmology.J Curr Ophthalmol. 2024 Aug 10;35(4):313-319. doi: 10.4103/joco.joco_178_23. eCollection 2023 Oct-Dec. J Curr Ophthalmol. 2024. PMID: 39281404 Free PMC article. Review.
Cited by
-
Application of sodium hyaluronate to the operation of suturing the corneal perforation.Int J Ophthalmol. 2010;3(3):269-71. doi: 10.3980/j.issn.2222-3959.2010.03.21. Epub 2010 Sep 18. Int J Ophthalmol. 2010. PMID: 22553570 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources