Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2002 May-Jun;12(3):212-8.
doi: 10.1177/112067210201200307.

Posterior capsular opacification in pseudophakic eyes with a silicone or acrylic intraocular lens

Affiliations
Clinical Trial

Posterior capsular opacification in pseudophakic eyes with a silicone or acrylic intraocular lens

T Pohjalainen et al. Eur J Ophthalmol. 2002 May-Jun.

Abstract

Purpose: To compare posterior capsular opacification in eyes with IOL of two different materials--silicone or acrylic.

Methods: Eighty consecutive eyes undergoing cataract surgery were prospectively randomized in two groups, 40 eyes receiving a silicone (Sl--30NB) and 40 eyes an acrylic (Acrysof MA60BM) intraocular lens (IOL). The same surgeon performed phacoemulsification and the intraocular lens (PHACO IOL) operation in all cases. Patients were re-examined on the first postoperative day, after one week, four months, and 1-2.4 years. Seven eyes were lost to late control.

Results: Clinically significant posterior capsular opacification (PCO) (including eyes with capsulotomy already performed) was equally common in both groups; 25% in the silicone group and 19% in the acrylic group (p=0.53). The posterior capsule remained clear in 61% of the silicone and 76% of the acrylic IOL eyes (p=0.18). In the whole study group, 29% of eyes with and 14% without concurrent ocular diseases had significant PCO (p=0.13). In the silicone IOL group, PCO was more common in eyes with concurrent ocular diseases (44%) than eyes without other diseases (10%) (p=0.049). Eyes with acrylic IOL showed no difference in significant PCO, with or without other diseases (18% and 20%, respectively).

Conclusions: In a consecutive series of 80 cataract eyes central PCO was equally common in eyes receiving a silicone or an acrylic IOL. In the silicone IOL group, however, significant PCO was more common if there was concurrent ocular disease, while with the acrylic IOL concurrent ocular disease did not seem to increase the risk of PCO.