Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2002 Jun;18(3):155-60.
doi: 10.1023/a:1014697208218.

Assessment of left ventricular diastolic function with Doppler tissue imaging: effects of preload and place of measurements

Affiliations

Assessment of left ventricular diastolic function with Doppler tissue imaging: effects of preload and place of measurements

Irem Dincer et al. Int J Cardiovasc Imaging. 2002 Jun.

Abstract

Mitral inflow velocities are widely used for the evaluation of left ventricular (LV) diastolic function. However, they are closely affected by other factors such as preload. The purpose of this study was to evaluate the usefulness of tissue Doppler velocities obtained from the mitral annulus for the evaluation of ventricular relaxation in patients under different loading conditions. We also evaluated the effect of preload at different sides on the mitral annulus. The study population consisted of 62 consecutive patients (38 male, 24 female with a mean age of 42 +/- 13 years) who have undergone hemodialysis. Both mitral inflow velocities (E wave, A wave, E wave deceleration time and isovolumetric relaxation time) and mitral annulus tissue Doppler velocities (E', A') from the septal, lateral, anterior, posterolateral and inferior sides of the mitral annulus were measured immediately before and after hemodialysis. Mitral inflow E and A wave velocities and E/A ratio decreased significantly (p < 0.001, p = 0.007, p < 0.001, respectively) after hemodialysis. Mitral annulus E' wave velocities and E'/A' ratios obtained from five different sides of the annulus also changed significantly (p < 0.001 for all); however, there was no change in the A' wave velocity (p > 0.05 for all) after hemodialysis. The decrease in E wave and E/A ratio in mitral inflow measurements and E' velocities and E'/A' ratios in tissue Doppler measurements were correlated with the amount of fluid extracted (for mitral inflow E wave, r = 0.392, p = 0.002 and E/A ratio, r = 0.280 and p = 0.027; for lateral side E', r = 0.329, p = 0.009 and E'/A' ratio, r = 0.286, p = 0.04; for septal side E', r = 0.376, p = 0.003 and E'/A' ratio, r = 0.297, p = 0.019; for anterior side E', r = 0.342, p = 0.007 and E'/A' ratio, r = 0.268, p = 0.035; for posterolateral side E', r = 0.423, p = 0.001 and E'/A' ratio, r = 0.343, p = 0.007; and for inferior side E', r = 0.326, p = 0.01 and E'/A' ratio, r = 0.278, p = 0.029). We conclude that mitral annular velocities obtained by tissue Doppler are preload dependent parameters for the evaluation of LV diastolic function.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Am Soc Echocardiogr. 1989 Sep-Oct;2(5):358-67 - PubMed
    1. J Clin Invest. 1976 Sep;58(3):751-60 - PubMed
    1. J Am Soc Echocardiogr. 1993 Mar-Apr;6(2):166-76 - PubMed
    1. J Am Coll Cardiol. 1988 Aug;12(2):426-40 - PubMed
    1. Circulation. 2000 Oct 10;102(15):1788-94 - PubMed