Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positions
- PMID: 12128110
- DOI: 10.1016/s0360-3016(02)02882-1
Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positions
Abstract
Purpose: To quantify three-dimensional (3D) movement of the prostate gland with the patient in the supine and prone positions and to analyze the movement frequency for each treatment position.
Methods and materials: The real-time tumor-tracking radiotherapy (RTRT) system was developed to identify the 3D position of a 2-mm gold marker implanted in the prostate 30 times/s using two sets of fluoroscopic images. The linear accelerator was triggered to irradiate the tumor only when the gold marker was located within the region of the planned coordinates relative to the isocenter. Ten patients with prostate cancer treated with RTRT were the subjects of this study. The coordinates of the gold marker were recorded every 0.033 s during RTRT in the supine treatment position for 2 min. The patient was then moved to the prone position, and the marker was tracked for 2 min to acquire data regarding movement in this position. Measurements were taken 5 times for each patient (once a week); a total of 50 sets for the 10 patients was analyzed. The raw data from the RTRT system were filtered to reduce system noise, and the amplitude of movement was then calculated. The discrete Fourier transform of the unfiltered data was performed for the frequency analysis of prostate movement.
Results: No apparent difference in movement was found among individuals. The amplitude of 3D movement was 0.1-2.7 mm in the supine and 0.4-24 mm in the prone positions. The amplitude in the supine position was statistically smaller in all directions than that in the prone position (p < 0.0001). The amplitude in the craniocaudal and AP directions was larger than in the left-right direction in the prone position (p < 0.0001). No characteristic movement frequency was detected in the supine position. The respiratory frequency was detected for all patients regarding movement in the craniocaudal and AP directions in the prone position. The results of the frequency analysis suggest that prostate movement is affected by the respiratory cycle and is influenced by bowel movement in the prone position.
Conclusion: The results of this study have confirmed that internal organ motion is less frequent in the supine position than in the prone position in the treatment of prostate cancer. RTRT would be useful in reducing uncertainty due to the effects of the respiratory cycle, especially in the prone position.
Similar articles
-
Tumor location, cirrhosis, and surgical history contribute to tumor movement in the liver, as measured during stereotactic irradiation using a real-time tumor-tracking radiotherapy system.Int J Radiat Oncol Biol Phys. 2003 May 1;56(1):221-8. doi: 10.1016/s0360-3016(03)00082-8. Int J Radiat Oncol Biol Phys. 2003. PMID: 12694842
-
Real-time tumor-tracking radiotherapy for adrenal tumors.Radiother Oncol. 2008 Jun;87(3):418-24. doi: 10.1016/j.radonc.2008.03.013. Epub 2008 Apr 23. Radiother Oncol. 2008. PMID: 18439693
-
Use of an implanted marker and real-time tracking of the marker for the positioning of prostate and bladder cancers.Int J Radiat Oncol Biol Phys. 2000 Dec 1;48(5):1591-7. doi: 10.1016/s0360-3016(00)00809-9. Int J Radiat Oncol Biol Phys. 2000. PMID: 11121666
-
Effect of intrafractional prostate motion on simultaneous boost intensity-modulated radiotherapy to the prostate: a simulation study based on intrafractional motion in the prone position.Med Dosim. 2015 Winter;40(4):325-32. doi: 10.1016/j.meddos.2015.04.003. Epub 2015 May 19. Med Dosim. 2015. PMID: 26002121
-
Three Dimensional Membrane Vibration Measurement Using a Two Dimensional Position Sensitive Device.Sensors (Basel). 2022 Dec 24;23(1):174. doi: 10.3390/s23010174. Sensors (Basel). 2022. PMID: 36616771 Free PMC article. Review.
Cited by
-
Current Research Status of Respiratory Motion for Thorax and Abdominal Treatment: A Systematic Review.Biomimetics (Basel). 2024 Mar 12;9(3):170. doi: 10.3390/biomimetics9030170. Biomimetics (Basel). 2024. PMID: 38534855 Free PMC article. Review.
-
ACR Appropriateness Criteria® external beam radiation therapy treatment planning for clinically localized prostate cancer, part I of II.Adv Radiat Oncol. 2016 Oct 20;2(1):62-84. doi: 10.1016/j.adro.2016.10.002. eCollection 2017 Jan-Mar. Adv Radiat Oncol. 2016. PMID: 28740916 Free PMC article. Review. No abstract available.
-
Intrafractional prostate motion during external beam radiotherapy monitored by a real-time target localization system.J Appl Clin Med Phys. 2015 Mar 8;16(2):5013. doi: 10.1120/jacmp.v16i2.5013. J Appl Clin Med Phys. 2015. PMID: 26103174 Free PMC article.
-
Intrafraction displacement of prone versus supine prostate positioning monitored by real-time electromagnetic tracking.J Appl Clin Med Phys. 2013 Mar 4;14(2):4141. doi: 10.1120/jacmp.v14i2.4141. J Appl Clin Med Phys. 2013. PMID: 23470943 Free PMC article. Clinical Trial.
-
Long-term results after external beam radiation therapy for T1-T2 localized prostate cancer.Curr Urol Rep. 2003 Jun;4(3):240-7. doi: 10.1007/s11934-003-0076-1. Curr Urol Rep. 2003. PMID: 12756089 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical