Assessment of the effect of hemoglobin variants on routine HbA1c measurements by electrospray ionization mass spectrometry
Abstract
We applied electrospray ionization mass spectrometry (ESI-MS) to identify hemoglobin (Hb) variants, and to assess the effect of the variants on routine measurements of a glycated Hb, HbA1c. Over the past 8 years, we have diagnosed 83 cases, including 42 kinds of variant Hb, using MS as the main technology. Of these variants, 3 were new, and 9 were the first cases in Japan. Some abnormal Hbs cause diseases, and most cause erroneous values of HbA1c measured by various methods. ESI-MS was also successfully used for the accurate determination of glycated Hb. We and other groups proposed methods to examine glycated Hb by ESI-MS using enzyme-digested peptides, or intact globin without enzyme digestion. Using the peptide method, we clarified the extent of discrepancies among the HbA1c values measured by conventional methods and accurate values for samples containing various Hb variants identified by the MS method. We applied the globin method to measure the ratio of the glycated component of a variant chain and that of a normal chain obtained from the same erythrocytes. Although the glycation degree on most variant chains was similar to that on normal chains obtained from the same erythrocytes, the content of the glycated component of a particular variant beta-chain was approximately three times as much as that of the normal beta-chain. Abnormal Hbs cause erroneous values for HbA1c to various extents with commercial measurement methods, and MS may offer an unrivaled strategy to correct these errors.
Similar articles
-
Potential of MALDI-TOF mass spectrometry to overcome the interference of hemoglobin variants on HbA1c measurement.Clin Chem Lab Med. 2020 Jul 17;59(1):233-239. doi: 10.1515/cclm-2020-0724. Clin Chem Lab Med. 2020. PMID: 32678801
-
Detection and identification of protein variants and adducts in blood and tissues: an application of soft ionization mass spectrometry to clinical diagnosis.J Chromatogr B Analyt Technol Biomed Life Sci. 2002 Aug 25;776(1):15-30. doi: 10.1016/s1570-0232(02)00031-4. J Chromatogr B Analyt Technol Biomed Life Sci. 2002. PMID: 12127321 Review.
-
Hemoglobin Raleigh results in factitiously low hemoglobin A1c when evaluated via immunoassay analyzer.J Diabetes Complications. 2011 Jan-Feb;25(1):14-8. doi: 10.1016/j.jdiacomp.2009.09.004. Epub 2009 Nov 6. J Diabetes Complications. 2011. PMID: 19896869
-
Quantification of glycated hemoglobin by electrospray ionization mass spectrometry.J Mass Spectrom. 1997 Jul;32(7):773-8. doi: 10.1002/(SICI)1096-9888(199707)32:7<773::AID-JMS533>3.0.CO;2-Y. J Mass Spectrom. 1997. PMID: 9241858
-
[Detection and characterization of aberrant blood proteins and quantification of glycated hemoglobin by mass spectrometry].Rinsho Byori. 1998 May;46(5):461-8. Rinsho Byori. 1998. PMID: 9627498 Review. Japanese.
Cited by
-
Determination of hemoglobin A1c and fasting blood glucose reference intervals in captive chimpanzees (Pan troglodytes).J Am Assoc Lab Anim Sci. 2011 Mar;50(2):165-70. J Am Assoc Lab Anim Sci. 2011. PMID: 21439208 Free PMC article.
-
Conditions associated with very low values of glycohaemoglobin measured by an HPLC method.J Clin Pathol. 2004 Apr;57(4):346-9. doi: 10.1136/jcp.2002.007088. J Clin Pathol. 2004. PMID: 15047733 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous