Doubt and certainty in counting
- PMID: 12143345
- DOI: 10.1016/S0079-6123(02)35005-2
Doubt and certainty in counting
Abstract
Some of the methods used for counting objects in histological sections are discussed. The method best suited for any particular counting program depends on many variables, which include the level of accuracy required, the type of preparation available for study, the size of the objects to be counted, the thickness of the sections that can be used, the equipment available and the amount of labor that can reasonably be invested. For light and electron microscopy, profile counts are simple and quick for objects that are small relative to section thickness and whose dimensions are readily defined. The 'physical disector' is particularly useful where objects to be counted are large relative to sections thickness, or where their dimensions are unknown or highly variable. For light microscopy, the optical disector is often easier to use. However, it makes more assumptions than the physical disector; some of these can introduce serious bias in the counts, and they are explored. Electron microscopy raises some special problems that relate to the depth of focus, the relatively very thin sections, and the tendency for thin structures that do not span the full thickness of a section to be lost or unrecognizable in some section planes. The importance of recognizing the assumptions that underlie any method of counting and its interpretation is stressed.
Similar articles
-
A new fractionator principle with varying sampling fractions: exemplified by estimation of synapse number using electron microscopy.J Microsc. 2006 Jun;222(Pt 3):251-5. doi: 10.1111/j.1365-2818.2006.01563.x. J Microsc. 2006. PMID: 16872424
-
[Synapse density determination in brain structures based on phosphotungstic acid contrast].J Hirnforsch. 1975;16(6):457-67. J Hirnforsch. 1975. PMID: 784872 German.
-
Use of frozen sections to determine neuronal number in the murine hippocampus and neocortex using the optical disector and optical fractionator.Brain Res Brain Res Protoc. 2004 Nov;14(1):45-57. doi: 10.1016/j.brainresprot.2004.09.003. Brain Res Brain Res Protoc. 2004. PMID: 15519951
-
On counting and counting errors.J Comp Neurol. 2002 May 20;447(1):1-7. doi: 10.1002/cne.10221. J Comp Neurol. 2002. PMID: 11967890 Review.
-
Application of the Golgi/electron microscopy technique for cell identification in immunocytochemical, retrograde labeling, and developmental studies of hippocampal neurons.Microsc Res Tech. 1992 Dec 1;23(4):306-23. doi: 10.1002/jemt.1070230406. Microsc Res Tech. 1992. PMID: 1295615 Review.
Cited by
-
A concise review of optical, physical and isotropic fractionator techniques in neuroscience studies, including recent developments.J Neurosci Methods. 2018 Dec 1;310:45-53. doi: 10.1016/j.jneumeth.2018.07.012. Epub 2018 Jul 23. J Neurosci Methods. 2018. PMID: 30048673 Free PMC article. Review.
-
Ultrastructure of primary afferent terminals and synapses in the rat nucleus of the solitary tract: comparison among the greater superficial petrosal, chorda tympani, and glossopharyngeal nerves.J Comp Neurol. 2007 Jun 20;502(6):1066-78. doi: 10.1002/cne.21371. J Comp Neurol. 2007. PMID: 17444498 Free PMC article.
-
Expression profiles of TRPV1, TRPV4, TLR4 and ERK1/2 in the dorsal root ganglionic neurons of a cancer-induced neuropathy rat model.PeerJ. 2018 Apr 4;6:e4622. doi: 10.7717/peerj.4622. eCollection 2018. PeerJ. 2018. PMID: 29637027 Free PMC article.
-
Optical disector counting in cryosections and vibratome sections underestimates particle numbers: effects of tissue quality.Microsc Res Tech. 2008 Jan;71(1):60-8. doi: 10.1002/jemt.20525. Microsc Res Tech. 2008. PMID: 17868132 Free PMC article.
-
Tumor microenvironment (Part I): Tissue integrity in a rat model of peripheral neural cancer.Heliyon. 2024 Jul 1;10(13):e33932. doi: 10.1016/j.heliyon.2024.e33932. eCollection 2024 Jul 15. Heliyon. 2024. PMID: 39050471 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources