Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2002 Jul;13(7):792-803.
doi: 10.1016/S1044-0305(02)00420-8.

A novel precursor ion discovery method on a hybrid quadrupole orthogonal acceleration time-of-flight (Q-TOF) mass spectrometer for studying protein phosphorylation

Affiliations
Free article

A novel precursor ion discovery method on a hybrid quadrupole orthogonal acceleration time-of-flight (Q-TOF) mass spectrometer for studying protein phosphorylation

R H Bateman et al. J Am Soc Mass Spectrom. 2002 Jul.
Free article

Abstract

A tandem quadrupole time-of-flight (Q-TOF) mass spectrometer has been programmed such that phosphorylated peptides can automatically be discovered and identified in a way similar to that of the use of precursor ion or neutral loss scanning, but without the need to scan the quadrupole mass filter. Instead, the method capitalizes on the innate capability of the Q-TOF to record mass spectra and product ion spectra quickly, with good sensitivity and with good mass accuracy. Alternate mass spectra, with and without fragmentation, are recorded at high and low collision energy with the quadrupole operating in wideband mode. The method of analysis is both compatible with and dependant on liquid chromatography for separation of complex mixtures. The method has been demonstrated by searching for the neutral loss of 98 Da (H3PO4) from phosphoserine and phosphothreonine residues, or for the phosphorylated immonium ion at m/z 216 from phosphotyrosine. The method also incorporates acquisition of the product ion spectrum from any candidate precursor ions, thereby allowing confirmation of the neutral loss or product ion and providing additional sequence information to assist identification of the protein and assign the site of phosphorylation.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Anal Biochem. 1994 May 15;219(1):9-20 - PubMed
    1. Anal Chem. 1996 Jan 1;68(1):1-8 - PubMed
    1. Cell. 2000 Jan 7;100(1):113-27 - PubMed
    1. J Mass Spectrom. 2001 Jul;36(7):782-90 - PubMed
    1. Electrophoresis. 2001 May;22(9):1652-68 - PubMed

LinkOut - more resources