Variability of serial same-day left ventricular ejection fraction using quantitative gated SPECT
- PMID: 12161712
- DOI: 10.1067/mnc.2002.122675
Variability of serial same-day left ventricular ejection fraction using quantitative gated SPECT
Abstract
Background: The accuracy of quantitative gated single photon emission computed tomography (SPECT) (QGS) and the potential limitations for estimation of left ventricular ejection fraction (LVEF) have been extensively evaluated. However, few studies have focused on the serial variability of QGS. This study was conducted to assess the serial variability of QGS for determination of LVEF between 2 sequential technetium 99m sestamibi-gated SPECT acquisitions at rest in both healthy and unhealthy subjects.
Methods and results: The study population consisted of 2 groups: group I included 21 volunteers with a low likelihood of CAD, and group II included 22 consecutive patients with documented CAD. Both groups underwent serial SPECT imaging. The overall correlation between sequential images was high (r = 0.94, SEE = 5.3%), and the mean serial variability of LVEF was 5.15% +/- 3.51%. Serial variability was lower for images with high counts (3.45% +/- 3.23%) than for images with low counts (6.85% +/- 3.77%). The mean serial variability was not different between normal and abnormal high-dose images (3.0% +/- 1.56% vs 3.9% +/- 2.77%). However, mean serial variability for images derived from abnormal low-dose images was significantly greater than that derived from normal low-dose images (9.6% +/- 2.22% vs 3.1% +/- 2.12%, P <.05).
Conclusions: Although QGS is an efficacious method to approximate LVEF values and is extremely valuable for incremental risk stratification of patients with coronary artery disease, it has significant variability in the estimation of LVEF on serial images. This should be taken into account when used for serial evaluation of LVEF.
Similar articles
-
Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT: MRI validation and comparison of the Emory Cardiac Tool Box with QGS and 4D-MSPECT.J Nucl Med. 2005 Aug;46(8):1256-63. J Nucl Med. 2005. PMID: 16085580 Clinical Trial.
-
Comparison of two software in gated myocardial perfusion single photon emission tomography, for the measurement of left ventricular volumes and ejection fraction, in patients with and without perfusion defects.Hell J Nucl Med. 2007 Jan-Apr;10(1):19-23. Hell J Nucl Med. 2007. PMID: 17450245
-
Validation of 4D-MSPECT and QGS for quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPET: comparison with cardiac magnetic resonance imaging.Eur J Nucl Med Mol Imaging. 2004 Apr;31(4):482-90. doi: 10.1007/s00259-003-1411-y. Epub 2004 Jan 14. Eur J Nucl Med Mol Imaging. 2004. PMID: 14722679 Clinical Trial.
-
Gated 99mTc-MIBI single-photon emission computed tomography for the evaluation of left ventricular ejection fraction: comparison with three-dimensional echocardiography.Ann Nucl Med. 2008 Oct;22(8):723-6. doi: 10.1007/s12149-008-0165-9. Epub 2008 Nov 4. Ann Nucl Med. 2008. PMID: 18982477
-
Validation of quantitative gated single photon emission computed tomography and an automated scoring system for the assessment of regional left ventricular systolic function.Nucl Med Commun. 2002 Sep;23(9):887-98. doi: 10.1097/00006231-200209000-00013. Nucl Med Commun. 2002. PMID: 12195094 Clinical Trial.
Cited by
-
Gated SPECT assessment of left ventricular function is sensitive to small patient motions and to low rates of triggering errors: a comparison with equilibrium radionuclide angiography.J Nucl Cardiol. 2005 Jan-Feb;12(1):78-85. doi: 10.1016/j.nuclcard.2004.08.008. J Nucl Cardiol. 2005. PMID: 15682368 Clinical Trial.
-
The expanding role of left ventricular functional assessment using gated myocardial perfusion SPECT: the supporting actor is stealing the scene.Eur J Nucl Med Mol Imaging. 2007 Jul;34(7):1107-22. doi: 10.1007/s00259-007-0405-6. Eur J Nucl Med Mol Imaging. 2007. PMID: 17384947 Review.
-
Stress-related variations in left ventricular function as assessed with gated myocardial perfusion SPECT.J Nucl Cardiol. 2003 Sep-Oct;10(5):456-63. doi: 10.1016/s1071-3581(03)00589-0. J Nucl Cardiol. 2003. PMID: 14569238 Clinical Trial.
-
Multicenter intercomparison assessment of consistency of left ventricular function from a gated cardiac SPECT phantom.J Nucl Cardiol. 2006 Nov;13(6):801-10. doi: 10.1016/j.nuclcard.2006.09.002. J Nucl Cardiol. 2006. PMID: 17174811
-
Reliability of myocardial perfusion gated SPECT for the reproducible evaluation of resting left ventricular functional parameters in long-term follow-up.Eur J Nucl Med Mol Imaging. 2010 Aug;37(9):1722-9. doi: 10.1007/s00259-010-1444-y. Eur J Nucl Med Mol Imaging. 2010. PMID: 20393711
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous