. 2002 Aug;122(2):451-6.
doi: 10.1378/chest.122.2.451.

Refillable oxygen cylinders may be an alternative for ambulatory oxygen therapy in COPD

Affiliations
Clinical Trial

Refillable oxygen cylinders may be an alternative for ambulatory oxygen therapy in COPD

Antoine Cuvelier et al. Chest. 2002 Aug.

Abstract

Study objectives: To compare, in clinical conditions, the efficacy of refilled oxygen cylinders (O2-HFs) in improving oxygenation and exercise capacity of patients with COPD during a 6-min walking test.

Design: Prospective randomized study with a cross-over design.

Setting: A university teaching hospital.

Patients: Ten patients with COPD, in a stable state and previously treated with long-term domiciliary oxygen therapy. Baseline characteristics were as follows: age, 65 +/- 7 years; PaO2 on room air, 55.4 +/- 6.3 mm Hg; PaCO2 on room air, 46.2 +/- 7.4 mm Hg; FEV1/vital capacity, 47 +/- 7%; and FEV1, 30 +/- 7% of predicted value (mean +/- SD).

Design: All patients performed three successive 6-min walking tests, the first test in room air and the other tests in a randomized order with either a conventional oxygen cylinder (O2-C) or an O2-HF.

Measurements and results: The fraction of inspired oxygen (FIO2) delivered by O2-HFs was significantly lower than the FIO2 delivered by O2-Cs (94.2 +/- 2.6% vs 98.8 +/- 4.9%, p = 0.02). Mean O2-HF and O2-C weights before the walking tests were similar (3,510 +/- 251 g and 3,770 +/- 142 g, respectively; p = 0.09). Mean transcutaneous oxygen saturation was similarly improved with both oxygen delivery systems. Mean distances with O2-C (373.5 +/- 81 m) and O2-HF (375 +/- 97 m) were not different but significantly improved, as compared with room air (334.5 +/- 90 m; p = 0.03 and 0.02, respectively). Dyspnea sensations were similar for the three tests.

Conclusion: O2-HFs are as efficient as O2-Cs for performing short-term exercises. Because of a lower cost, pressurizing units may be worthwhile for improving ambulatory oxygen therapy and pulmonary rehabilitation programs.