. 2002 Aug 15:2:13.
doi: 10.1186/1471-2458-2-13. Epub 2002 Aug 15.

Identification of bacteria in drinking and purified water during the monitoring of a typical water purification system

Affiliations

Identification of bacteria in drinking and purified water during the monitoring of a typical water purification system

Vessoni Thereza Christina Penna et al. BMC Public Health. .

Abstract

Background: A typical purification system that provides purified water which meets ionic and organic chemical standards, must be protected from microbial proliferation to minimize cross-contamination for use in cleaning and preparations in pharmaceutical industries and in health environments.

Methodology: Samples of water were taken directly from the public distribution water tank at twelve different stages of a typical purification system were analyzed for the identification of isolated bacteria. Two miniature kits were used: (i) identification system (api 20 NE, Bio-Mérieux) for non-enteric and non-fermenting gram-negative rods; and (ii) identification system (BBL crystal, Becton and Dickson) for enteric and non-fermenting gram-negative rods. The efficiency of the chemical sanitizers used in the stages of the system, over the isolated and identified bacteria in the sampling water, was evaluated by the minimum inhibitory concentration (MIC) method.

Results: The 78 isolated colonies were identified as the following bacteria genera: Pseudomonas, Flavobacterium and Acinetobacter. According to the miniature kits used in the identification, there was a prevalence of isolation of P. aeruginosa 32.05%, P. picketti (Ralstonia picketti) 23.08%, P. vesiculares 12.82%,P. diminuta 11.54%, F. aureum 6.42%, P. fluorescens 5.13%, A. lwoffi 2.56%, P. putida 2.56%, P. alcaligenes 1.28%, P. paucimobilis 1.28%, and F. multivorum 1.28%.

Conclusions: We found that research was required for the identification of gram-negative non-fermenting bacteria, which were isolated from drinking water and water purification systems, since Pseudomonas genera represents opportunistic pathogens which disperse and adhere easily to surfaces, forming a biofilm which interferes with the cleaning and disinfection procedures in hospital and industrial environments.

PubMed Disclaimer

References

    1. Brazilian Ministry of Health Directives n° 15/MS/ANVS n°211/MS/ANVS 1999, n ° 196/MS/AVNS 1983, n° 36/MS/AVNS 1991, n° 113/MS/AVNS 1993, n° 122/DTN 1993, n° 211/MS/ANVS 1999, and Health Sanitation Code n° 12342, 1988.
    1. The United States Pharmacopoeia National Formulary Water For Pharmaceutical Purposes USP 24/NF. 2000. pp. 2154–2165.
    1. Schreckenberger PC, Janda JM, Wong JD, Baron EJ. Algorithms for identification of aerobic gram-negative bacteria. In: Murray PR, editor. Manual of Clinical Microbiology. 7. Washington, American Society For Microbiology; 1999. pp. 438–452.
    1. Palmieri MJ, Caritó SL, Meyer RF. Comparison of rapid NFT and API 20 NE with conventional methods for the identification of gram-negative non-fermentative bacilli from pharmaceutics and cosmetics. Appl Environ Microbiol. 1988;54:2838–2841. - PMC - PubMed
    1. Vessoni Penna TC, Mazzola PG, Martins AM. The efficacy of chemical agents in cleaning and desinfection programs for hospital nurseries. J BMC Infectious Diseases. 2001;1:16. doi: 10.1186/1471-2334-1-16. - DOI - PMC - PubMed

Publication types

MeSH terms

LinkOut - more resources