The influence of sodium hypochlorite irrigation on the accuracy of the Root ZX electronic apex locator
- PMID: 12184422
- DOI: 10.1097/00004770-200208000-00008
The influence of sodium hypochlorite irrigation on the accuracy of the Root ZX electronic apex locator
Abstract
The purpose of this in vitro investigation was to determine whether the presence of sodium hypochlorite influences the accuracy of the Root ZX electronic apex locator. Forty, extracted, human teeth were mounted in an experimental apparatus. After achieving ideal access, working length measurements were obtained using the Root ZX. The canals were flushed with 2.125% sodium hypochlorite and measurements were again made with the electronic apex locator. Before measuring a third time, 5.25% sodium hypochlorite was then administered to each canal. Finally, the tooth was removed from the apparatus and the actual canal length was determined by measuring a file brought to the apical constriction (verified by direct visualization). No significant differences were found between the experimental groups. Overall, Root ZX measurements were within 0.5 mm of the actual length 83% of the time. The results of this study indicate that the Root ZX is not adversely affected by the presence of sodium hypochlorite.
Similar articles
-
An ex vivo comparison of working length determination by 3 electronic apex locators.Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2009 Sep;108(3):e147-51. doi: 10.1016/j.tripleo.2009.04.040. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2009. PMID: 19716484 Clinical Trial.
-
Influence of apical constriction diameter on Root ZX apex locator precision.J Endod. 2007 Aug;33(8):995-8. doi: 10.1016/j.joen.2007.05.009. J Endod. 2007. PMID: 17878091
-
Ex vivo comparison of the accuracy of Root ZX II in detecting apical constriction using different meter's reading.Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2009 Jul;108(1):e41-5. doi: 10.1016/j.tripleo.2009.03.009. Epub 2009 May 22. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2009. PMID: 19464208 Clinical Trial.
-
Electronic apex locator.Dent Clin North Am. 2004 Jan;48(1):35-54. doi: 10.1016/j.cden.2003.10.005. Dent Clin North Am. 2004. PMID: 15066506 Review.
-
[Canal Finder System 89!!! Improvements and indications after 4 years of experimentation and use].Rev Odontostomatol (Paris). 1990 Jul-Aug;19(4):327-36. Rev Odontostomatol (Paris). 1990. PMID: 2237106 Review. French.
Cited by
-
Comparison of two electronic apex locators on human cadavers.Clin Oral Investig. 2016 Sep;20(7):1547-50. doi: 10.1007/s00784-015-1644-8. Epub 2015 Nov 4. Clin Oral Investig. 2016. PMID: 26531192
-
Evaluation of Dentaport ZX and Raypex 6 electronic apex locators: an in vivo study.Med Oral Patol Oral Cir Bucal. 2014 Mar 1;19(2):e202-5. doi: 10.4317/medoral.19114. Med Oral Patol Oral Cir Bucal. 2014. PMID: 24121908 Free PMC article.
-
Efficiency of 2 electronic apex locators on working length determination: A clinical study.J Conserv Dent. 2013 May;16(3):229-32. doi: 10.4103/0972-0707.111320. J Conserv Dent. 2013. PMID: 23833456 Free PMC article.
-
In vitro Evaluation of the Accuracy of the Root Zx in the Presence of Naocl 2.5% and Chlorhexidine 0.2.J Clin Exp Dent. 2018 Nov 1;10(11):e1054-e1057. doi: 10.4317/jced.54193. eCollection 2018 Nov. J Clin Exp Dent. 2018. PMID: 30607220 Free PMC article.
-
Efficiency of an Integrated Apex Locator in Determining Working Length in Various Irrigating Solutions: An In Vivo Study.J Pharm Bioallied Sci. 2020 Aug;12(Suppl 1):S410-S414. doi: 10.4103/jpbs.JPBS_122_20. Epub 2020 Aug 28. J Pharm Bioallied Sci. 2020. PMID: 33149496 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous