Blood values of juvenile northern elephant seals (Mirounga angustirostris) obtained using a portable clinical analyzer
- PMID: 12189595
- DOI: 10.1111/j.1939-165x.2002.tb00288.x
Blood values of juvenile northern elephant seals (Mirounga angustirostris) obtained using a portable clinical analyzer
Abstract
Background: Sick, injured, or orphaned juvenile northern elephant seals (Mirounga angustisrostris) treated at rehabilitation centers frequently present with abnormalities in blood sodium, potassium, chloride, BUN, and glucose concentrations, and HCT. These abnormalities could be detected rapidly using a portable blood analyzer, but results with this analysis method do not necessarily equate with those obtained using other techniques.
Objective: The objective of this study was to better assess the clinical relevance of values obtained from a portable analyzer and to compare the results with values obtained using more common methods of analysis.
Methods: Heparinized whole blood samples were collected from 20 rehabilitated juvenile northern elephant seals. A portable clinical analyzer (i-STAT, i-STAT Corp, East Windsor, NJ, USA) was used to establish baseline values. Serum biochemical values were obtained using an automated chemical analyzer (Olympus AU5200, Olympus America, Melville, NY, USA). HCT was determined using EDTA whole blood and a cell counter.
Results: Using the portable analyzer, mean (minimum-maximum) values were obtained for sodium, 143 (132-146) mmol/L; potassium, 4.4 (3.9-5.8) mmol/L; chloride, 106 (101-109) mmol/L; BUN, 1.8 (1.1-2.4) mmol/L; glucose, 7.55 (5.99-8.49) mmol/L; and HCT, 0.55 (0.52-0.61) L/L. Average differences between methods were small for potassium (-0.45 mmol/L), BUN (0.1 mmol/L), and HCT (0.037 L/L) but were large for sodium (-6.8 mmol/L), chloride (-6.4 mmol/L), and glucose (-0.56 mmol/L).
Conclusions: These results suggest that the i-STAT portable analyzer could be useful for clinically assessing juvenile elephant seals. However, when making medical decisions, the clinician should be aware of differences associated with various analyzers and sample types.
Similar articles
-
Hematologic and serum biochemical profile of the northern elephant seal (Mirounga angustirostris): variation with age, sex, and season.J Wildl Dis. 2008 Oct;44(4):911-21. doi: 10.7589/0090-3558-44.4.911. J Wildl Dis. 2008. PMID: 18957647
-
Evaluation of a portable clinical analyzer in a veterinary hospital setting.J Am Vet Med Assoc. 1998 Sep 1;213(5):691-4. J Am Vet Med Assoc. 1998. PMID: 9731265
-
Reference values for serum biochemical parameters in free-ranging harp seals.Vet Clin Pathol. 2002;31(3):98-105. doi: 10.1111/j.1939-165x.2002.tb00287.x. Vet Clin Pathol. 2002. PMID: 12189594
-
Measurement of ionized calcium in canine blood samples collected in prefilled and self-filled heparinized syringes using the i-STAT point-of-care analyzer.Vet Clin Pathol. 2008 Mar;37(1):66-72. doi: 10.1111/j.1939-165X.2008.00001.x. Vet Clin Pathol. 2008. PMID: 18366547
-
Evaluation of a portable clinical analyzer in cynomolgus Macaques (Macaca fasicularis).J Am Assoc Lab Anim Sci. 2007 May;46(3):53-7. J Am Assoc Lab Anim Sci. 2007. PMID: 17487954
Cited by
-
Use of portable blood physiology point-of-care devices for basic and applied research on vertebrates: a review.Conserv Physiol. 2014 Apr 4;2(1):cou011. doi: 10.1093/conphys/cou011. eCollection 2014. Conserv Physiol. 2014. PMID: 27293632 Free PMC article.
-
Validation of the i-STAT and HemoCue systems for the analysis of blood parameters in the bar-headed goose, Anser indicus.Conserv Physiol. 2015 May 19;3(1):cov021. doi: 10.1093/conphys/cov021. eCollection 2015. Conserv Physiol. 2015. PMID: 27293706 Free PMC article.
-
Obtaining accurate glucose measurements from wild animals under field conditions: comparing a hand held glucometer with a standard laboratory technique in grey seals.Conserv Physiol. 2017 Feb 27;5(1):cox013. doi: 10.1093/conphys/cox013. eCollection 2017. Conserv Physiol. 2017. PMID: 28413683 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources