Serum reference intervals and diagnostic ranges for free kappa and free lambda immunoglobulin light chains: relative sensitivity for detection of monoclonal light chains
- PMID: 12194920
Serum reference intervals and diagnostic ranges for free kappa and free lambda immunoglobulin light chains: relative sensitivity for detection of monoclonal light chains
Abstract
Background: The detection of monoclonal free light chains (FLCs) is an important diagnostic aid for a variety of monoclonal gammopathies and is especially important in light-chain diseases, such as light-chain myeloma, primary systemic amyloidosis, and light-chain-deposition disease. These diseases are more prevalent in the elderly, and assays to detect and quantify abnormal amounts of FLCs require reference intervals that include elderly donors.
Methods: We used an automated immunoassay for FLCs and sera from a population 21-90 years of age. We used the calculated reference and diagnostic intervals to compare FLC results with those obtained by immunofixation (IFE) to detect low concentrations of monoclonal kappa and lambda FLCs in the sera of patients with monoclonal gammopathies.
Results: Serum kappa and lambda FLCs increased with population age, with an apparent change for those >80 years. This trend was lost when the FLC concentration was normalized to cystatin C concentration. The ratio of kappa FLC to lambda FLC (FLC K/L) did not exhibit an age-dependent trend. The diagnostic interval for FLC K/L was 0.26-1.65. The 95% reference interval for kappa FLC was 3.3-19.4 mg/L, and that for lambda FLC was 5.7-26.3 mg/L. Detection and quantification of monoclonal FLCs by nephelometry were more sensitive than IFE in serum samples from patients with primary systemic amyloidosis and light-chain-deposition disease.
Conclusions: Reference and diagnostic intervals for serum FLCs have been developed for use with a new, automated immunoassay that makes the detection and quantification of monoclonal FLCs easier and more sensitive than with current methods. The serum FLC assay complements IFE and allows quantification of FLCs in light-chain-disease patients who have no detectable serum or urine M-spike.
Similar articles
-
Detection of kappa and lambda light chain monoclonal proteins in human serum: automated immunoassay versus immunofixation electrophoresis.Clin Vaccine Immunol. 2006 Feb;13(2):277-80. doi: 10.1128/CVI.13.2.277-280.2006. Clin Vaccine Immunol. 2006. PMID: 16467338 Free PMC article.
-
Clinical usefulness of free light chain concentration as a tumor marker in multiple myeloma.Ann Hematol. 2005 Sep;84(9):588-93. doi: 10.1007/s00277-005-1047-z. Epub 2005 May 10. Ann Hematol. 2005. PMID: 15883850
-
Diagnostic performance of quantitative kappa and lambda free light chain assays in clinical practice.Clin Chem. 2005 May;51(5):878-81. doi: 10.1373/clinchem.2004.046870. Epub 2005 Mar 17. Clin Chem. 2005. PMID: 15774572
-
Serum free light chains in clinical laboratory diagnostics.Clin Chim Acta. 2014 Jan 1;427:15-20. doi: 10.1016/j.cca.2013.08.018. Epub 2013 Aug 30. Clin Chim Acta. 2014. PMID: 23999048 Review.
-
Inter-assay variability in automated serum free light chain assays and their use in the clinical laboratory.Crit Rev Clin Lab Sci. 2020 Mar;57(2):73-85. doi: 10.1080/10408363.2019.1670133. Epub 2019 Oct 15. Crit Rev Clin Lab Sci. 2020. PMID: 31612753 Review.
Cited by
-
Serum free light-chain assay for the detection and monitoring of multiple myeloma and related conditions.Ther Adv Hematol. 2013 Feb;4(1):37-41. doi: 10.1177/2040620712466863. Ther Adv Hematol. 2013. PMID: 23610612 Free PMC article.
-
Clinical course of light-chain smouldering multiple myeloma (idiopathic Bence Jones proteinuria): a retrospective cohort study.Lancet Haematol. 2014 Oct 1;1(1):e28-e36. doi: 10.1016/S2352-3026(14)70001-8. Lancet Haematol. 2014. PMID: 25530988 Free PMC article.
-
Assessment of free light chains in the cerebrospinal fluid of patients with lymphomatous meningitis - a pilot study.BMC Cancer. 2007 Oct 3;7:185. doi: 10.1186/1471-2407-7-185. BMC Cancer. 2007. PMID: 17915026 Free PMC article.
-
Oral amyloidosis: A case report and diagnostic algorithm.J Oral Maxillofac Pathol. 2021 Sep-Dec;25(3):559. doi: 10.4103/jomfp.JOMFP_227_20. Epub 2022 Jan 11. J Oral Maxillofac Pathol. 2021. PMID: 35281154 Free PMC article.
-
Elevated serum free light chains are associated with inferior event free and overall survival in Hodgkin lymphoma.Am J Hematol. 2011 Dec;86(12):998-1000. doi: 10.1002/ajh.22168. Epub 2011 Oct 17. Am J Hematol. 2011. PMID: 22006790 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical