The importance of the location of fluorodeoxyglucose uptake in periprosthetic infection in painful hip prostheses
- PMID: 12195089
- DOI: 10.1097/00006231-200209000-00008
The importance of the location of fluorodeoxyglucose uptake in periprosthetic infection in painful hip prostheses
Abstract
Ten per cent of patients with hip replacement will eventually complain of significant pain after surgery, often requiring a revision arthroplasty. The majority of these patients experience aseptic loosening rather than infection. Despite significant advances made in diagnostic imaging, distinguishing infection from aseptic loosening remains a significant challenge. Imaging using fluorodeoxyglucose (FDG) positron emission tomography (PET) has been reported to have excellent sensitivity in detecting infections associated with hip prostheses. However, in some studies, a high rate of false positive results has been reported, especially when increased tracer uptake adjacent to the prosthesis (which is not surrounded by bone) is used as the sole criterion for diagnosing infection. The objective of this investigation was to determine the optimal criteria for diagnosing periprosthetic infection, thereby avoiding false positive results in this setting. A total of 41 total hip arthroplasties from 32 patients and for whom complete clinical follow-up was available were included in this analysis. The location and intensity of FDG uptake were determined for each scan. Final diagnosis was made by microbiology, histopathology, surgical findings and clinical follow-up. Patients who did not undergo surgery were followed up to at least 9 months. Twelve patients were proven eventually to have periprosthetic infection. Images from 11 of these patients displayed increased tracer uptake along the interface between bone and prosthesis. The intensity of the increased tracer uptake varied from mild to moderate, with standardized uptake values less than 2. In contrast, images from uninfected, loose hip prostheses revealed very intense uptake around the head or neck of the prosthesis with standardized uptake values as high as 7. It is concluded that the intensity of increased FDG uptake is less important than the location of increased FDG uptake when FDG PET is used to diagnose periprosthetic infection in patients with hip arthroplasty. Using increased uptake as the sole criterion for diagnosing infection will result in false positive results in this setting.
Similar articles
-
Fluorodeoxyglucose positron emission tomography imaging for diagnosing periprosthetic hip infection: the importance of diagnostic criteria.Int Orthop. 2018 Sep;42(9):2025-2034. doi: 10.1007/s00264-018-3931-x. Epub 2018 Apr 20. Int Orthop. 2018. PMID: 29679108
-
The implications of 18F-FDG PET for the diagnosis of endoprosthetic loosening and infection in hip and knee arthroplasty: results from a prospective, blinded study.BMC Musculoskelet Disord. 2006 Mar 3;7:20. doi: 10.1186/1471-2474-7-20. BMC Musculoskelet Disord. 2006. PMID: 16512924 Free PMC article.
-
Persistent non-specific FDG uptake on PET imaging following hip arthroplasty.Eur J Nucl Med Mol Imaging. 2002 Oct;29(10):1328-33. doi: 10.1007/s00259-002-0886-2. Epub 2002 Jul 18. Eur J Nucl Med Mol Imaging. 2002. PMID: 12271415 Clinical Trial.
-
Critical role of 18F-labeled fluorodeoxyglucose PET in the management of patients with arthroplasty.Radiol Clin North Am. 2007 Jul;45(4):711-8, vii. doi: 10.1016/j.rcl.2007.05.010. Radiol Clin North Am. 2007. PMID: 17706535 Review.
-
The role of FDG-PET in distinguishing between septic and aseptic loosening in hip prosthesis: a review of literature.Int Orthop. 2009 Feb;33(1):1-5. doi: 10.1007/s00264-008-0575-2. Epub 2008 Jul 2. Int Orthop. 2009. PMID: 18594820 Free PMC article. Review.
Cited by
-
A Systematic Review and Meta-Analysis on the Accuracy of Fluorodeoxyglucose Positron Emission Tomography/ Computerized Tomography for Diagnosing Periprosthetic Joint Infections.Front Surg. 2022 Jun 1;9:698781. doi: 10.3389/fsurg.2022.698781. eCollection 2022. Front Surg. 2022. PMID: 35722526 Free PMC article. Review.
-
Growing applications of FDG PET-CT imaging in non-oncologic conditions.J Biomed Res. 2015 May;29(3):189-202. doi: 10.7555/JBR.29.20140081. Epub 2015 Mar 8. J Biomed Res. 2015. PMID: 26060443 Free PMC article.
-
Potential usefulness of 68Ga-citrate PET/CT in detecting infected lower limb prostheses.EJNMMI Res. 2019 Jan 3;9(1):2. doi: 10.1186/s13550-018-0468-3. EJNMMI Res. 2019. PMID: 30607646 Free PMC article.
-
Diagnostic accuracy of positron emission tomography/computerized tomography for periprosthetic joint infection of hip: systematic review and meta-analysis.J Orthop Surg Res. 2023 Aug 30;18(1):640. doi: 10.1186/s13018-023-04061-4. J Orthop Surg Res. 2023. PMID: 37644493 Free PMC article.
-
An easy and practical guide for imaging infection/inflammation by [18F]FDG PET/CT.Clin Transl Imaging. 2021;9(4):283-297. doi: 10.1007/s40336-021-00435-y. Epub 2021 Jun 1. Clin Transl Imaging. 2021. PMID: 34095006 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources