Decreased laboratory testing for lecithin-to-sphingomyelin ratio and phosphatidylglycerol after fetal lung maturity assessment from lamellar body count in amniotic fluid
- PMID: 12201546
Decreased laboratory testing for lecithin-to-sphingomyelin ratio and phosphatidylglycerol after fetal lung maturity assessment from lamellar body count in amniotic fluid
Abstract
The objectives of this study were to do inexpensive lamellar body count (LBC) in amniotic fluid, to do statistical analysis to evaluate cutoff values for fetal lung maturity (FLM) and fetal lung immaturity (FLI), to derive a threshold for obtaining a lecithin-to-sphingomyelin (L/S) ratio and phosphatidylglycerol percentage (%PG), and to determine the potential cost savings to the hospital if they use this new method. Testing (LBC, L/S ratio, and %PG) was done on 123 specimens of amniotic fluid. Receiver operating characteristic (ROC) curve, discriminant, linear regression, chi2, and cost analyses were used to evaluate the laboratory and financial parameters. Lamellar body counts of greater than 41,500 (Coulter MAXM: sensitivity, 90.5%; specificity, 87.7%; positive predictive value, 79.2%; negative predictive value, 94.7%) and greater than 32,000 (Coulter Gen.S: sensitivity, 90.5%; specificity, 85.2%; positive predictive value, 76.0%; negative predictive value, 94.5%) were the best threshold for biochemical FLM. Similarly, LBC of less than 24,000 (MAXM: sensitivity, 78.6%; specificity, 100%; positive predictive value, 100%; negative predictive value, 90.0%) and less than 21,000 (Gen.S: sensitivity, 71.4%; specificity, 100%; positive predictive value, 100%; negative predictive value, 87.1%) provided the best statistical cutoff for biochemical FLI from discriminant analysis. The authors concluded that FLM and FLI can be predicted with reasonable accuracy from LBC in amniotic fluid specimens. The expensive and not easily accessible L/S ratio and %PG can then be done only in cases in which LBC indicates transitional FLM. A cascade approach results in 86% savings to the hospital if the L/S ratio and %PG are not sent to a reference laboratory.
Similar articles
-
Lecithin/sphingomyelin ratio and lamellar body count. What values predict the presence of phosphatidylglycerol?J Reprod Med. 2003 May;48(5):330-4. J Reprod Med. 2003. PMID: 12815904 Clinical Trial.
-
Gestational age-specific predicted risk of neonatal respiratory distress syndrome using lamellar body count and surfactant-to-albumin ratio in amniotic fluid.Am J Obstet Gynecol. 2005 Nov;193(5):1680-4. doi: 10.1016/j.ajog.2005.03.080. Am J Obstet Gynecol. 2005. PMID: 16260210
-
A comparison of the accuracy of the TDx-FLM assay, lecithin-sphingomyelin ratio, and phosphatidylglycerol in the prediction of neonatal respiratory distress syndrome.Obstet Gynecol. 1993 Dec;82(6):1004-8. Obstet Gynecol. 1993. PMID: 8233250
-
Assessment of foetal lung maturity.Eur Respir J Suppl. 1989 Mar;3:40s-49s. Eur Respir J Suppl. 1989. PMID: 2662995 Review.
-
[Specifications on the lecithin/sphingomyelin ratio (L/S). Updated review].Rev Clin Esp. 1993 Mar;192(4):185-8. Rev Clin Esp. 1993. PMID: 8480064 Review. Spanish.
Cited by
-
Diagnostic accuracy of lamellar body count as a predictor of fetal lung maturity: A systematic review and meta-analysis.Eur J Obstet Gynecol Reprod Biol X. 2019 May 31;5:100059. doi: 10.1016/j.eurox.2019.100059. eCollection 2020 Jan. Eur J Obstet Gynecol Reprod Biol X. 2019. PMID: 32021970 Free PMC article. Review.