Liquid chromatographic resolution of gemifloxacin mesylate on a chiral stationary phase derived from crown ether
- PMID: 12210509
- DOI: 10.1002/bmc.164
Liquid chromatographic resolution of gemifloxacin mesylate on a chiral stationary phase derived from crown ether
Abstract
A new racemic fluoroquinolone antibacterial agent, gemifloxacin mesylate, has been successfully resolved on a chiral stationary phase (CSP) derived from (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid. Compared to the Crownpak CR(+) column, the CSP used in this study was more effective for the resolution of racemic gemifloxacin mesylate, especially in terms of analytical time. The resolution of gemifloxacin mesylate enantiomers on the CSP was found to be dependent on the type and content of organic and acidic modifiers in the aqueous mobile phase and the column temperature.
Copyright 2002 John Wiley & Sons, Ltd.