Preliminary report on in vivo coronary MRA at 3 Tesla in humans
- PMID: 12210906
- DOI: 10.1002/mrm.10240
Preliminary report on in vivo coronary MRA at 3 Tesla in humans
Abstract
Current limitations of coronary magnetic resonance angiography (MRA) include a suboptimal signal-to-noise ratio (SNR), which limits spatial resolution and the ability to visualize distal and branch vessel coronary segments. Improved SNR is expected at higher field strengths, which may provide improved spatial resolution. However, a number of potential adverse effects on image quality have been reported at higher field strengths. The limited availability of high-field systems equipped with cardiac-specific hardware and software has previously precluded successful in vivo human high-field coronary MRA data acquisition. In the present study we investigated the feasibility of human coronary MRA at 3.0 T in vivo. The first results obtained in nine healthy adult subjects are presented.
Copyright 2002 Wiley-Liss, Inc.
Similar articles
-
Sensitivity-encoded coronary MRA at 3T.Magn Reson Med. 2004 Aug;52(2):221-7. doi: 10.1002/mrm.20062. Magn Reson Med. 2004. PMID: 15282803
-
Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3.0 T: comparison with steady-state free precession technique at 1.5 T.Invest Radiol. 2008 Sep;43(9):663-8. doi: 10.1097/RLI.0b013e31817ed1ff. Invest Radiol. 2008. PMID: 18708861
-
High spatial resolution coronary magnetic resonance angiography at 7 T: comparison with low spatial resolution bright blood imaging.Invest Radiol. 2014 May;49(5):326-30. doi: 10.1097/RLI.0000000000000047. Invest Radiol. 2014. PMID: 24637588
-
Neurovascular imaging at 1.5 tesla versus 3.0 tesla.Magn Reson Imaging Clin N Am. 2009 Feb;17(1):29-46. doi: 10.1016/j.mric.2008.12.005. Magn Reson Imaging Clin N Am. 2009. PMID: 19364598 Review.
-
High temporal and high spatial resolution MR angiography (4D-MRA).Rofo. 2014 Sep;186(9):847-59. doi: 10.1055/s-0034-1366661. Epub 2014 Jun 23. Rofo. 2014. PMID: 24955647 Review.
Cited by
-
Non-enhanced and Non-gated MR Angiography for Robust Visualization of Peripheral Arteries Using Enhanced Acceleration-selective Arterial Spin Labeling (eAccASL).Magn Reson Med Sci. 2021 Sep 1;20(3):312-319. doi: 10.2463/mrms.tn.2019-0172. Epub 2020 Jul 13. Magn Reson Med Sci. 2021. PMID: 32655087 Free PMC article.
-
Recent Advances in Cardiac Magnetic Resonance Imaging.Korean Circ J. 2019 Feb;49(2):146-159. doi: 10.4070/kcj.2018.0246. Epub 2018 Nov 20. Korean Circ J. 2019. PMID: 30468040 Free PMC article. Review.
-
Robust volume-targeted balanced steady-state free-precession coronary magnetic resonance angiography in a breathhold at 3.0 Tesla: a reproducibility study.J Cardiovasc Magn Reson. 2014 Apr 23;16(1):27. doi: 10.1186/1532-429X-16-27. J Cardiovasc Magn Reson. 2014. PMID: 24758168 Free PMC article.
-
Single-breath-hold whole-heart coronary MRA in healthy volunteers at 3.0-T MRI.Springerplus. 2014 Nov 11;3:667. doi: 10.1186/2193-1801-3-667. eCollection 2014. Springerplus. 2014. PMID: 25485202 Free PMC article.
-
Comparison of left ventricular function assessment using phonocardiogram- and electrocardiogram-triggered 2D SSFP CINE MR imaging at 1.5 T and 3.0 T.Eur Radiol. 2010 Jun;20(6):1344-55. doi: 10.1007/s00330-009-1676-z. Epub 2009 Dec 16. Eur Radiol. 2010. PMID: 20013275
MeSH terms
LinkOut - more resources
Full Text Sources