Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2002 Jun;40(6):568-73.
doi: 10.1515/CCLM.2002.098.

Immunoassay of anti-thyroid autoantibodies: high analytical variability in second generation methods

Affiliations

Immunoassay of anti-thyroid autoantibodies: high analytical variability in second generation methods

Renato Tozzoli et al. Clin Chem Lab Med. 2002 Jun.

Abstract

The use of highly sensitive immunometric methods in clinical laboratories to assay anti-thyroid antibodies has progressively expanded in recent years but it is not known whether the new techniques have improved the analytical variability connected with the preceding methodologies. The Italian Society of Laboratory Medicine Study Group on Autoimmune Diseases conducted a collaborative study with the biomedical industry to evaluate the degree of standardization of the new analytical procedures. Twelve companies agreed to participate in the study on the search for anti-thyroglobulin (anti-Tg) and anti-thyroperoxidase (anti-TPO) antibodies in nine sera from patients with autoimmune thyroiditis, and in six sera from patients with non-autoimmune thyroid disease; ten immunometric and three immunofluorescence methods were employed. Agreement of qualitative results was close to 90% for anti-Tg and 97% for anti-TPO, with no important differences between the methods; variability of the quantitative results, expressed as CV% of absolute (in lU/ml) and relative (in cut-off concentration multiples) values was 93.9% and 102.3%, respectively, for anti-Tg, and 75.5% and 62.9%, respectively, for anti-TPO. These findings show that despite the progressive improvement in the analytical techniques, the variability between methods for the assay of anti-Tg and anti-TPO is still unexpectedly high, and probably due to several factors such as uncertainty in defining the positive cutoff concentration, absence of adequate international reference preparations, modality of autoantigen purification, and analytical variability in the assay procedures.

PubMed Disclaimer