Effects of fluoride and dissolved oxygen concentrations on the corrosion behavior of pure titanium and titanium alloys
- PMID: 12238790
- DOI: 10.4012/dmj.21.83
Effects of fluoride and dissolved oxygen concentrations on the corrosion behavior of pure titanium and titanium alloys
Abstract
The effects of dissolved-oxygen concentration and fluoride concentration on the corrosion behaviors of commercial pure titanium, Ti-6Al-4V and Ti-6Al-7Nb alloys and experimentally produced Ti-0.2Pd and Ti-0.5Pt alloys were examined using the corrosion potential measurements. The amount of dissolved Ti was analyzed by inductively coupled plasma mass spectroscopy. A decrease in the dissolved-oxygen concentration tended to reduce the corrosion resistance of Ti and Ti alloys. If there was no fluoride, however, corrosion did not occur. Under low dissolved-oxygen conditions, the corrosion of pure Ti and Ti-6Al-4V and Ti-6Al-7Nb alloys might easily take place in the presence of small amounts of fluoride. They were corroded by half or less of the fluoride concentrations in commercial dentifrices. The Ti-0.2Pd and Ti-0.5Pt alloys did not corrode more, even under the low dissolved-oxygen conditions and a fluoride-containing environment, than pure Ti and Ti-6Al-4V and Ti-6Al-7Nb alloys. These alloys are expected to be useful as new Ti alloys with high corrosion resistance in dental use.
Similar articles
-
Corrosion behavior of pure titanium and titanium alloys in fluoride-containing solutions.Dent Mater J. 2001 Dec;20(4):305-14. doi: 10.4012/dmj.20.305. Dent Mater J. 2001. PMID: 11915624
-
The development of Ti alloys for dental implant with high corrosion resistance and mechanical strength.Dent Mater J. 2007 Mar;26(2):260-7. doi: 10.4012/dmj.26.260. Dent Mater J. 2007. PMID: 17621943
-
The effect of Pt and Pd alloying additions on the corrosion behavior of titanium in fluoride-containing environments.Biomaterials. 2005 May;26(15):2239-46. doi: 10.1016/j.biomaterials.2004.07.022. Biomaterials. 2005. PMID: 15585225
-
Comparative analysis of corrosion resistance between beta titanium and Ti-6Al-4V alloys: A systematic review.J Trace Elem Med Biol. 2020 Dec;62:126618. doi: 10.1016/j.jtemb.2020.126618. Epub 2020 Jul 9. J Trace Elem Med Biol. 2020. PMID: 32663743
-
Fluoride induced corrosion affecting Titanium brackets: A systematic review.Int Orthod. 2018 Dec;16(4):603-612. doi: 10.1016/j.ortho.2018.09.003. Epub 2018 Oct 9. Int Orthod. 2018. PMID: 30314953
Cited by
-
The effect of fluoride-containing oral rinses on the corrosion resistance of titanium alloy (Ti-6Al-4V).Korean J Orthod. 2017 Sep;47(5):306-312. doi: 10.4041/kjod.2017.47.5.306. Epub 2017 Jul 27. Korean J Orthod. 2017. PMID: 28861392 Free PMC article.
-
Effects of 2% sodium fluoride solution on the prevention of streptococcal adhesion to titanium and zirconia surfaces.Sci Rep. 2021 Feb 24;11(1):4498. doi: 10.1038/s41598-021-84096-x. Sci Rep. 2021. PMID: 33627733 Free PMC article.
-
Magnesium-Titanium Alloys: A Promising Solution for Biodegradable Biomedical Implants.Materials (Basel). 2024 Oct 23;17(21):5157. doi: 10.3390/ma17215157. Materials (Basel). 2024. PMID: 39517433 Free PMC article. Review.
-
Biomimetic coatings enhance tribocorrosion behavior and cell responses of commercially pure titanium surfaces.Biointerphases. 2016 Sep 11;11(3):031008. doi: 10.1116/1.4960654. Biointerphases. 2016. PMID: 27514370 Free PMC article.
-
[Effects of copper content on the antibacterial performance and corrosion resistance of CoCrMoCu alloy].Hua Xi Kou Qiang Yi Xue Za Zhi. 2018 Apr 1;36(2):178-183. doi: 10.7518/hxkq.2018.02.012. Hua Xi Kou Qiang Yi Xue Za Zhi. 2018. PMID: 29779280 Free PMC article. Chinese.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources