Complications of inhaled anesthesia delivery systems
- PMID: 12298305
- DOI: 10.1016/s0889-8537(02)00008-1
Complications of inhaled anesthesia delivery systems
Abstract
Inhaled anesthesia delivery systems (ADS) have evolved in the past 20 years from simple pneumatic machines to complex computer-controlled devices. For the purposes of this discussion, we will outline some of the potential complications that may result from the use of these systems. Because of the complexity of modern ADS, it is incumbent on the anesthesiologist to be cognizant of potential problems that may arise with their use. Even though it is now more difficult than ever for the practitioner to develop a comprehensive understanding of these machines, it remains essential for the safe practice of anesthesia. When the anesthesiologist understands the basic design differences between products from different manufacturers, it is more likely that the appropriate preoperative checks will be performed and that delivery of a safe anesthetic can be ensured. Although malpractice claims associated with anesthesia delivery systems are rare, when they do occur they may be severe, and they continue to occur. These complications may range in severity from mild hypercapnia to awareness and even death.
Similar articles
-
Another cause of hypercapnia during induction of anesthesia.Paediatr Anaesth. 2010 Nov;20(11):1055. doi: 10.1111/j.1460-9592.2010.03424.x. Paediatr Anaesth. 2010. PMID: 20964773 No abstract available.
-
Special aspects of pharmacokinetics of inhalation anesthesia.Handb Exp Pharmacol. 2008;(182):159-86. doi: 10.1007/978-3-540-74806-9_8. Handb Exp Pharmacol. 2008. PMID: 18175091 Review.
-
Pressure-flow characteristics of breathing systems and their components for pediatric and adult patients.Paediatr Anaesth. 2018 Jan;28(1):37-45. doi: 10.1111/pan.13284. Epub 2017 Nov 17. Paediatr Anaesth. 2018. PMID: 29148150
-
Inhaled anesthesia: the original closed-loop drug administration paradigm.Clin Pharmacol Ther. 2008 Jul;84(1):15-8. doi: 10.1038/clpt.2008.85. Clin Pharmacol Ther. 2008. PMID: 18563068 Review.
-
Preoperative checkout procedures for modern anesthesia machines in an emergency situation.Can J Anaesth. 2003 Dec;50(10):1081; author reply 1081-2. doi: 10.1007/BF03018385. Can J Anaesth. 2003. PMID: 14656801 No abstract available.
Cited by
-
Anaesthesia machine: checklist, hazards, scavenging.Indian J Anaesth. 2013 Sep;57(5):533-40. doi: 10.4103/0019-5049.120151. Indian J Anaesth. 2013. PMID: 24249887 Free PMC article. Review.
-
Failure to ventilate: Technical error.Saudi J Anaesth. 2013 Jan;7(1):99-100. doi: 10.4103/1658-354X.109853. Saudi J Anaesth. 2013. PMID: 23717246 Free PMC article. No abstract available.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous