High-resolution, spin-echo BOLD, and CBF fMRI at 4 and 7 T
- PMID: 12353274
- DOI: 10.1002/mrm.10252
High-resolution, spin-echo BOLD, and CBF fMRI at 4 and 7 T
Abstract
With growing interest in noninvasive mapping of columnar organization and other small functional structures in the brain, achieving high spatial resolution and specificity in fMRI is of critical importance. We implemented a simple method for BOLD and perfusion fMRI with high spatial resolution and specificity. Increased spatial resolution was achieved by selectively exciting a slab of interest along the phase-encoding direction for EPI, resulting in a reduced FOV and number of phase-encoding steps. Improved spatial specificity was achieved by using SE EPI acquisition at high fields, where it is predominantly sensitive to signal changes in the microvasculature. Robust SE BOLD and perfusion fMRI were obtained with a nominal in-plane resolution up to 0.5 x 0.5 mm(2) at 7 and 4 Tesla, and were highly reproducible under repeated measures. This methodology enables high-resolution and high-specificity studies of functional topography in the millimeter to submillimeter spatial scales of the human brain.
Copyright 2002 Wiley-Liss, Inc.
Comment in
-
Specificity of high-resolution BOLD and CBF fMRI at 7 T.Magn Reson Med. 2004 Mar;51(3):644-5; author reply 646-7. doi: 10.1002/mrm.20040. Magn Reson Med. 2004. PMID: 15004812 No abstract available.
Similar articles
-
BOLD sensitivity and SNR characteristics of parallel imaging-accelerated single-shot multi-echo EPI for fMRI.Neuroimage. 2014 Jan 1;84:65-75. doi: 10.1016/j.neuroimage.2013.08.007. Epub 2013 Aug 15. Neuroimage. 2014. PMID: 23954488
-
Specificity of high-resolution BOLD and CBF fMRI at 7 T.Magn Reson Med. 2004 Mar;51(3):644-5; author reply 646-7. doi: 10.1002/mrm.20040. Magn Reson Med. 2004. PMID: 15004812 No abstract available.
-
Spin-echo fMRI in humans using high spatial resolutions and high magnetic fields.Magn Reson Med. 2003 Apr;49(4):655-64. doi: 10.1002/mrm.10433. Magn Reson Med. 2003. PMID: 12652536
-
Spin-echo fMRI: The poor relation?Neuroimage. 2012 Aug 15;62(2):1109-15. doi: 10.1016/j.neuroimage.2012.01.003. Epub 2012 Jan 8. Neuroimage. 2012. PMID: 22245351 Review.
-
High spatial resolution functional magnetic resonance imaging at very-high-magnetic field.Top Magn Reson Imaging. 1999 Feb;10(1):63-78. doi: 10.1097/00002142-199902000-00006. Top Magn Reson Imaging. 1999. PMID: 10389673 Review.
Cited by
-
Coupling Genetic Addiction Risk Score (GARS) and Pro Dopamine Regulation (KB220) to Combat Substance Use Disorder (SUD).Glob J Addict Rehabil Med. 2017 Feb;1(2):555556. doi: 10.19080/GJARM.2017.01.555556. Epub 2017 Feb 23. Glob J Addict Rehabil Med. 2017. PMID: 29399668 Free PMC article. No abstract available.
-
Small tip angle three-dimensional tailored radiofrequency slab-select pulse for reduced B1 inhomogeneity at 3 T.Magn Reson Med. 2005 Feb;53(2):479-84. doi: 10.1002/mrm.20358. Magn Reson Med. 2005. PMID: 15678525 Free PMC article.
-
High resolution SE-fMRI in humans at 3 and 7 T using a motor task.MAGMA. 2008 Mar;21(1-2):113-20. doi: 10.1007/s10334-007-0099-6. Epub 2007 Dec 18. MAGMA. 2008. PMID: 18087739
-
Test-Retest Reliability of Synchrony and Metastability in Resting State fMRI.Brain Sci. 2021 Dec 31;12(1):66. doi: 10.3390/brainsci12010066. Brain Sci. 2021. PMID: 35053813 Free PMC article.
-
High resolution data analysis strategies for mesoscale human functional MRI at 7 and 9.4T.Neuroimage. 2018 Jan 1;164:48-58. doi: 10.1016/j.neuroimage.2017.03.058. Epub 2017 Apr 14. Neuroimage. 2018. PMID: 28416453 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical