Inversion profiles of adiabatic inversion pulses for flowing spins: the effects on labeling efficiency and labeling accuracy in perfusion imaging with pulsed arterial spin-labeling
- PMID: 12361796
- DOI: 10.1016/s0730-725x(02)00525-8
Inversion profiles of adiabatic inversion pulses for flowing spins: the effects on labeling efficiency and labeling accuracy in perfusion imaging with pulsed arterial spin-labeling
Abstract
The inversion profile of adiabatic inversion pulses is essential to the accuracy of perfusion measurement with pulsed arterial spin-labeling (ASL). In this paper, the inversion profiles for flowing spins were investigated using a numerical solution of the modified Bloch equations including a term for moving spins. Inversion profiles for spins flowing at a constant or varying velocity were examined for hyperbolic secant (HS) and frequency-offset corrected inversion (FOCI) pulses. Distortions of the inversion profiles were found for both pulses with spins flowing within physiological velocity range. The effects of the distorted profiles on labeling efficiency and labeling accuracy in the application of pulsed ASL perfusion imaging were analyzed. These effects should be taken into account in ASL techniques, in order to obtain robust and accurate perfusion measurements.
Similar articles
-
Optimization of adiabatic pulses for pulsed arterial spin labeling at 7 tesla: Comparison with pseudo-continuous arterial spin labeling.Magn Reson Med. 2021 Jun;85(6):3227-3240. doi: 10.1002/mrm.28661. Epub 2021 Jan 11. Magn Reson Med. 2021. PMID: 33427349 Free PMC article.
-
Efficiency of inversion pulses for background suppressed arterial spin labeling.Magn Reson Med. 2005 Aug;54(2):366-72. doi: 10.1002/mrm.20556. Magn Reson Med. 2005. PMID: 16032674
-
Comparison of Myocardial Blood Flow Quantification Models for Double ECG Gating Arterial Spin Labeling MRI: Reproducibility Assessment.J Magn Reson Imaging. 2024 Oct;60(4):1577-1588. doi: 10.1002/jmri.29220. Epub 2024 Jan 11. J Magn Reson Imaging. 2024. PMID: 38206090
-
Tissue specific perfusion imaging using arterial spin labeling.NMR Biomed. 1994 Mar;7(1-2):75-82. doi: 10.1002/nbm.1940070112. NMR Biomed. 1994. PMID: 8068529 Review.
-
Arterial Spin Labeling Perfusion of the Brain: Emerging Clinical Applications.Radiology. 2016 Nov;281(2):337-356. doi: 10.1148/radiol.2016150789. Radiology. 2016. PMID: 27755938 Review.
Cited by
-
Arterial spin labeling for the measurement of cerebral perfusion and angiography.J Cereb Blood Flow Metab. 2018 Apr;38(4):603-626. doi: 10.1177/0271678X17743240. Epub 2017 Nov 23. J Cereb Blood Flow Metab. 2018. PMID: 29168667 Free PMC article. Review.
-
Arterial transit time effects in pulsed arterial spin labeling CBF mapping: insight from a PET and MR study in normal human subjects.Magn Reson Med. 2010 Feb;63(2):374-84. doi: 10.1002/mrm.22218. Magn Reson Med. 2010. PMID: 19953506 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Medical