Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2002 Oct;33(10):2402-7.
doi: 10.1161/01.str.0000030111.34093.02.

Detection of carotid artery stenosis by in vivo duplex ultrasound: correlation with planimetric measurements of the corresponding postmortem specimens

Affiliations

Detection of carotid artery stenosis by in vivo duplex ultrasound: correlation with planimetric measurements of the corresponding postmortem specimens

Gernot Schulte-Altedorneburg et al. Stroke. 2002 Oct.

Abstract

Background and purpose: The correct detection and quantification of carotid artery disease are of decisive impact on patient prognosis and adequate treatment. In this study, we evaluated the ability of ultrasonography to detect and to grade carotid artery stenosis through a comparison of the in vivo ultrasound findings with the planimetric analysis of the corresponding postmortem specimens.

Methods: Shortly before their death, 59 critically ill neurological patients (mean age, 70 years) were prospectively examined by extracranial and intracranial Doppler sonography and color-coded duplex ultrasound. Carotid stenosis was classified by hemodynamic and morphological ultrasound criteria. Carotid specimens were removed in toto during autopsy. Under standardized conditions, specimens were redistended, sectioned, and histologically processed. Computerized planimetric measurements of the arteries were carried out and compared with the ultrasound findings. Correlation of the ultrasound and postmortem planimetric findings was available in 93 carotid bifurcations.

Results: Through both techniques, 46 carotid arteries were found to be normal. Steno-occlusive carotid lesions ranged from 8.5% to 100% lumen reduction. Overall, r=0.96 and adjusted R(2)=0.90. For the steno-occlusive carotid lesions, r=0.91.

Conclusions: Extracranial and intracranial Doppler and color-coded duplex ultrasound permits reliable detection and quantification of carotid artery stenoses and occlusions even under difficult examination conditions in critically ill patients.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources