Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2002 Oct 1;309(1):127-36.
doi: 10.1016/s0003-2697(02)00265-8.

Analytical validation of a real-time reverse transcription-polymerase chain reaction quantitation of different transcripts of the Wilms' tumor suppressor gene (WT1)

Affiliations

Analytical validation of a real-time reverse transcription-polymerase chain reaction quantitation of different transcripts of the Wilms' tumor suppressor gene (WT1)

Catherine I Dumur et al. Anal Biochem. .

Abstract

Transcript variants of the same gene may play distinct functions in the tissue where they are expressed. Absolute quantitation of different transcript variants in malignant and normal tissues can address the specific role of each particular isoform in cancer development and progression. We have recently demonstrated differential expression of the wild-type Wilms' tumor transcript (wtWT1) and a novel truncated WT1 transcript (trWT1) which lacks the first five exons of wtWT1, among human prostate cancer, leukemia, and breast cancer cell lines. Here we report the analytical validation of a real-time RT-PCR assay for the absolute quantitation of these two different WT1 transcripts with specific primers and probes that ensure specificity for each WT1 variant. By cloning each WT1 transcript in a T3 promoter-containing plasmid, we obtained two WT1 transcript-specific in vitro-generated RNA calibrators for absolute quantitation. Serial dilution of each RNA calibrator demonstrated a 5 log linear dynamic range (5 x 10(1) to 5 x 10(6) copies/reaction, R(2)=0.9963 for wtWT1 and R(2)=0.9993 for trWT1). Dilution of the calibrators in total RNA from 1 x 10(3) non-WT1-expressing cells showed a decreased sensitivity without affecting the linear dynamic range. Precision studies for values within the linear dynamic range showed a coefficient of variation of less than 4% for both transcripts. The described method provides a sensitive and reliable technique for quantitating different WT1 mRNA transcripts.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources