Microdosimetric interpretation of the photon energy response of LiF:Mg,Ti detectors
- PMID: 12382842
- DOI: 10.1093/oxfordjournals.rpd.a005826
Microdosimetric interpretation of the photon energy response of LiF:Mg,Ti detectors
Abstract
Photon energy response of MTS-N (LiF:Mg,Ti) detectors (TLD Poland) and of MTS-N detectors sensitised with 200 Gy of 60Co gamma rays, followed by UV irradiation (sMTS-N), has been determined using X rays with narrow energy spectra, in the energy range from 20 to 300 keV. The over-response of LiF:Mg,Ti detectors for X rays (relative TL efficiency eta = 1.1) can be explained as an ionisation density effect. Low energy X rays produce short electron tracks, which locally deposit a high radiation dose and, consequently, lead to an enhanced (supralinear) response. This over-response has not been observed in sensitised MTS-N where supralinearity in the response after gamma ray doses above 1 Gy is not seen. Using the dose-response curves measured for MTS-N detectors after 137Cs gamma ray irradiation and local doses calculated using Monte Carlo generated electron tracks, it was possible to predict the relative TL effectiveness for different X ray energies. The calculation procedure can be applied to predict the photon energy response of LiF:Mg,Ti detectors in an arbitrary photon field.
Similar articles
-
Thermoluminescent response of LiF:Mg,Ti to 20 keV electrons.Radiat Prot Dosimetry. 2002;100(1-4):179-82. doi: 10.1093/oxfordjournals.rpd.a005842. Radiat Prot Dosimetry. 2002. PMID: 12382856
-
Response of LiF:Mg,Ti thermoluminescent dosimeters at photon energies relevant to the dosimetry of brachytherapy (<1 MeV).Med Phys. 2011 Oct;38(10):5539-50. doi: 10.1118/1.3633892. Med Phys. 2011. PMID: 21992372
-
Characterisation of thermoluminescent LiF:Mg,Ti (MTS-N) detectors in the 85-550 K temperature range.Radiat Prot Dosimetry. 2002;100(1-4):297-300. doi: 10.1093/oxfordjournals.rpd.a005872. Radiat Prot Dosimetry. 2002. PMID: 12382882
-
The effects of ionisation density on the thermoluminescence response (efficiency) of LiF:Mg,Ti and LiF:Mg,Cu,P.Radiat Prot Dosimetry. 2004;109(4):331-48. doi: 10.1093/rpd/nch310. Radiat Prot Dosimetry. 2004. PMID: 15273352 Review.
-
The application of LiF:Mg,Cu,P to large scale personnel dosimetry: current status and future directions.Radiat Prot Dosimetry. 2006;119(1-4):248-54. doi: 10.1093/rpd/nci692. Epub 2006 Jul 11. Radiat Prot Dosimetry. 2006. PMID: 16835277 Review.
Cited by
-
Investigation of the ionisation density dependence of the glow curve characteristics of LIF:MG,TI (TLD-100).Radiat Prot Dosimetry. 2008;131(4):406-13. doi: 10.1093/rpd/ncn197. Epub 2008 Jul 29. Radiat Prot Dosimetry. 2008. PMID: 18667402 Free PMC article.
-
Dosimetric Study of Heat-Treated Calcium-Aluminum-Silicon Borate Dosimeter for Diagnostic Radiology Applications.Sensors (Basel). 2023 Jan 16;23(2):1011. doi: 10.3390/s23021011. Sensors (Basel). 2023. PMID: 36679808 Free PMC article.
-
Use of Thermoluminescence Dosimetry for QA in High-Dose-Rate Skin Surface Brachytherapy with Custom-Flap Applicator.Sensors (Basel). 2023 Mar 30;23(7):3592. doi: 10.3390/s23073592. Sensors (Basel). 2023. PMID: 37050652 Free PMC article.
-
MICRODOSIMETRIC UNDERSTANDING OF DOSE RESPONSE AND RELATIVE EFFICIENCY OF THERMOLUMINESCENCE DETECTORS.Radiat Prot Dosimetry. 2020 Dec 30;192(2):165-177. doi: 10.1093/rpd/ncaa211. Radiat Prot Dosimetry. 2020. PMID: 33418564 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials
Miscellaneous