A survey of radiation dose associated with pediatric plain-film chest X-ray examinations
- PMID: 12389103
- DOI: 10.1007/s00247-002-0734-3
A survey of radiation dose associated with pediatric plain-film chest X-ray examinations
Abstract
Background: The effective doses delivered to pediatric patients are not well characterized for many plain-film X-ray examination techniques. The few data available on clinical doses in pediatric radiology are generally outdated because of the changes in X-ray generators and hardware that have taken place over the past decade.
Objective: This survey characterizes X-ray examination techniques and measures effective doses delivered to a phantom representing a 1 year old in order to identify specific examination features that may result in greater than necessary doses to pediatric patients.
Materials and methods: An anthropomorphic phantom representing a 1 year old was developed for use as a survey tool. The phantom incorporates direct reading metal oxide semiconductor field effect transistor (MOSFET) dosimeters that permit the effective dose to be measured for clinical examinations. Seventeen commonly performed examinations were characterized at ten facilities with doses determined for a chest series of exams at each facility.
Results: The survey demonstrates that the effective dose for a given examination can vary by an order of magnitude between institutions. Distributions of examination parameters identified those that are most significant for minimizing patient dose.
Conclusion: Efforts spent to determine pediatric specific radiographic techniques contribute more to effective imaging with low patient doses than utilizing AEC controls or high-frequency generators.
Similar articles
-
Effective dose determination using an anthropomorphic phantom and metal oxide semiconductor field effect transistor technology for clinical adult body multidetector array computed tomography protocols.J Comput Assist Tomogr. 2007 Jul-Aug;31(4):544-9. doi: 10.1097/RCT.0b013e31802d3dd2. J Comput Assist Tomogr. 2007. PMID: 17882029
-
A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): cylindrical and anthropomorphic phantoms.Phys Med Biol. 2005 Sep 7;50(17):3989-4004. doi: 10.1088/0031-9155/50/17/005. Epub 2005 Aug 11. Phys Med Biol. 2005. PMID: 16177525
-
[Radiation exposure of children in pediatric radiology. Part 3: Conversion coefficients for reconstruction of organ doses achieved during chest X-ray examinations].Rofo. 2008 Dec;180(12):1061-81. doi: 10.1055/s-2008-1027890. Epub 2008 Nov 28. Rofo. 2008. PMID: 19235700 German.
-
Assessment of the problem: pediatric doses in screen-film and digital radiography.Pediatr Radiol. 2004 Oct;34 Suppl 3:S173-82; discussion S234-41. doi: 10.1007/s00247-004-1267-8. Pediatr Radiol. 2004. PMID: 15558259 Review.
-
[Radiation exposure of children in pediatric radiology part 8: radiation doses during thoracoabdominal babygram and abdominal X-ray examination of the newborn and young infants].Rofo. 2010 Jun;182(6):479-92. doi: 10.1055/s-0028-1109963. Epub 2010 Jan 18. Rofo. 2010. PMID: 20084594 Review. German.
Cited by
-
Revisit image control for pediatric chest radiography.Radiat Med. 2007 Feb;25(2):60-4. doi: 10.1007/s11604-006-0103-5. Epub 2007 Feb 27. Radiat Med. 2007. PMID: 17541514
-
Unnecessary irradiation to non-thoracic structures during pediatric chest radiography.Pediatr Radiol. 2006 Jan;36(1):22-5. doi: 10.1007/s00247-005-0016-y. Epub 2005 Oct 21. Pediatr Radiol. 2006. PMID: 16240140
-
Estimation of radiation exposure of children undergoing superselective intra-arterial chemotherapy for retinoblastoma treatment: assessment of local diagnostic reference levels as a function of age, sex, and interventional success.Neuroradiology. 2021 Mar;63(3):391-398. doi: 10.1007/s00234-020-02540-7. Epub 2020 Aug 29. Neuroradiology. 2021. PMID: 32862237 Free PMC article.
-
Factors contributing to uncertainty in paediatric abdominal ultrasound reports in the paediatric emergency department.BMC Emerg Med. 2023 Oct 10;23(1):120. doi: 10.1186/s12873-023-00892-w. BMC Emerg Med. 2023. PMID: 37817121 Free PMC article.
-
Radiation safety.Pediatr Radiol. 2009 Jun;39 Suppl 3:385-90. doi: 10.1007/s00247-009-1215-8. Pediatr Radiol. 2009. PMID: 19440758 Review. No abstract available.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Miscellaneous