Biosensors for in vivo glucose measurement: can we cross the experimental stage
- PMID: 12392956
- DOI: 10.1016/s0956-5663(02)00099-4
Biosensors for in vivo glucose measurement: can we cross the experimental stage
Abstract
The development of in vivo working glucose sensors needs two decades, so far. The availability of long term functional implantable biosensors for continuous glucose measurings is a basic prerequisite for the individualized optimum insulin treatment of diabetics. Enzymatic electrochemical sensors are described which realize a functional stability over more than 2 years in vitro, however their function in vivo is limited due to certain bioincompatibility expressed by inflammation of the surrounding tissue, exudates, and immun reactions. The paper reflects an overview concerning different sensor covering materials used as more or less suitable diffusion membranes. From experimental studies in animals and human volunteers conclusions are drawn for further developmental steps of biosensors for in vivo use and for the applicability of glucose sensors for transient diagnostic purposes and as a basis for glucose controlled therapeutic measures. The results demonstrate that further progress aimed at long term biostability of implanted biosensors needs to solve technological problems and the serial production of sensors with really comparable qualities as a prerequisite for clinical trials.
Similar articles
-
Novel planar glucose biosensors for continuous monitoring use.Biosens Bioelectron. 2005 Apr 15;20(10):1993-2000. doi: 10.1016/j.bios.2004.09.010. Biosens Bioelectron. 2005. PMID: 15741068
-
Sensor and biosensor based on Prussian Blue modified gold and platinum screen printed electrodes.Biosens Bioelectron. 2003 Mar;18(2-3):193-200. doi: 10.1016/s0956-5663(02)00185-9. Biosens Bioelectron. 2003. PMID: 12485765
-
Murine model of implantable glucose sensors: a novel model for glucose sensor development.Diabetes Technol Ther. 2005 Oct;7(5):727-37; discussion 738-40. doi: 10.1089/dia.2005.7.727. Diabetes Technol Ther. 2005. PMID: 16241876
-
Implantable electrochemical sensors for biomedical and clinical applications: progress, problems, and future possibilities.Curr Med Chem. 2007;14(8):937-51. Curr Med Chem. 2007. PMID: 17430145 Review.
-
Advanced biosensors for glucose and insulin.Biosens Bioelectron. 2019 Sep 15;141:111201. doi: 10.1016/j.bios.2019.03.034. Epub 2019 Mar 19. Biosens Bioelectron. 2019. PMID: 31302426 Review.
Cited by
-
A review of the biocompatibility of implantable devices: current challenges to overcome foreign body response.J Diabetes Sci Technol. 2008 Nov;2(6):1003-15. doi: 10.1177/193229680800200610. J Diabetes Sci Technol. 2008. PMID: 19885290 Free PMC article.
-
Controlled Drug Delivery: Historical perspective for the next generation.J Control Release. 2015 Dec 10;219:2-7. doi: 10.1016/j.jconrel.2015.10.005. Epub 2015 Oct 9. J Control Release. 2015. PMID: 26456749 Free PMC article.
-
Continuously Operating Biosensor and Its Integration into a Hermetically Sealed Medical Implant.Micromachines (Basel). 2016 Oct 9;7(10):183. doi: 10.3390/mi7100183. Micromachines (Basel). 2016. PMID: 30404356 Free PMC article.
-
Biosensors in clinical chemistry: An overview.Adv Biomed Res. 2014 Jan 27;3:67. doi: 10.4103/2277-9175.125848. eCollection 2014. Adv Biomed Res. 2014. PMID: 24627875 Free PMC article. Review.
-
Single walled carbon nanotubes as reporters for the optical detection of glucose.J Diabetes Sci Technol. 2009 Mar 1;3(2):242-52. doi: 10.1177/193229680900300204. J Diabetes Sci Technol. 2009. PMID: 20144355 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical