Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1975 May;38(3):663-72.
doi: 10.1152/jn.1975.38.3.663.

Analysis of response properties of deefferented mammalian spindle receptors based on frequency response

Analysis of response properties of deefferented mammalian spindle receptors based on frequency response

Z Hasan et al. J Neurophysiol. 1975 May.

Abstract

Sinusoidal responses of primary and secondary endings in deefferented spindles of anesthetized cats were studied over the low-frequency range 0.001-0.1 Hz. Stretch amplitudes were chosen conservatively small (25-100 mum peak-to-peak) so as to lie within the linear region. 1. At 0.1 Hz average sensitivity was 350 pps/mm for primary endings and 80 pps/mm for secondary endings. Sensitivity fell to lower values at lower frequencies, but even at 0.001 Hz, corresponding to 17 min/cycle, sensitivity remained elevated above static values determined with large stretches. Phase lead varied from 5 to 50 degrees and, in the case of primary endings, tended to be greater at lower frequencies. 2. Except for the different scaling factors, the only apparent difference between the frequency responses of primary and secondary endings was a tendency for primary endings to show a greater phase lead over the range 0.001-0.01 Hz. 3. Dynamic responsiveness was assessed theoretically from frequency-response data by calculating responses to ramps at various velocities. Over most of the velocity range dynamic responses were not proportional to velocity. The greater dynamic responsiveness of primary endings during large (6 mm) ramp stretches might be related to frequency response below 0.01 Hz. 4. Certain aspects of dynamic responsiveness to large ramps (6 mm) were accounted for by assuming all phases of responses were attenuated by 25 dB in the case of primary endings and 20 dB in the case of secondary endings. The nonlinearity responsible for attenuation appears to occur at an early stage in the sensory process. 5. Comparison of individual responses to slow ramps with predictions based on linear theory indicated the presence of abrupt departures from linearity for both primary and secondary endings.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources