Gas chromatography-mass spectrometry method for determination of phenylalanine and tyrosine in neonatal blood spots
- PMID: 12401368
- DOI: 10.1016/s1570-0232(02)00632-3
Gas chromatography-mass spectrometry method for determination of phenylalanine and tyrosine in neonatal blood spots
Abstract
In this paper we developed a simple, rapid and sensitive method for the quantitative analysis of phenylalanine (Phe) and tyrosine (Tyr) in dried blood spots of newborns by gas chromatography-mass spectrometry (GC-MS). Phe and Tyr in blood samples were reacted with N-methyl-N-(tert.-butyldimethylsilyl)trifluoroacetamide at 120 degrees C for 30 min and their corresponding single derivatives were obtained. Phe and Tyr were determined by measurement of their derivatives by GC-MS in the selected ion monitoring mode. Contents of Phe and Tyr in blood spots were calculated by external standard method. The ratio of Phe to Tyr was used for neonatal screening for phenylketonuria. The present method only took a few minutes to perform and required minimal sample preparation. In addition it provided low detection limits of 1.2 micromol l(-1) for Phe and 1.6 micromol l(-1)for Tyr.
Copyright 2002 Elsevier Science B.V.
Similar articles
-
Use of phenylalanine-to-tyrosine ratio determined by tandem mass spectrometry to improve newborn screening for phenylketonuria of early discharge specimens collected in the first 24 hours.Clin Chem. 1998 Dec;44(12):2405-9. Clin Chem. 1998. PMID: 9836704
-
Quantification of derivatized phenylalanine and tyrosine in dried blood spots using liquid chromatography with tandem spectrometry for newborn screening of phenylketonuria.Eur J Mass Spectrom (Chichester). 2024 Apr;30(2):133-140. doi: 10.1177/14690667241229626. Epub 2024 Feb 6. Eur J Mass Spectrom (Chichester). 2024. PMID: 38321764
-
Amino acid analysis of dried blood spots for diagnosis of phenylketonuria using capillary electrophoresis-mass spectrometry equipped with a sheathless electrospray ionization interface.Anal Bioanal Chem. 2013 Oct;405(25):8063-72. doi: 10.1007/s00216-013-6999-6. Epub 2013 May 15. Anal Bioanal Chem. 2013. PMID: 23673571
-
The use of mass spectrometry to analyze dried blood spots.Mass Spectrom Rev. 2016 May-Jun;35(3):361-438. doi: 10.1002/mas.21441. Epub 2014 Sep 22. Mass Spectrom Rev. 2016. PMID: 25252132 Review.
-
Glycomacropeptide: long-term use and impact on blood phenylalanine, growth and nutritional status in children with PKU.Orphanet J Rare Dis. 2019 Feb 15;14(1):44. doi: 10.1186/s13023-019-1011-y. Orphanet J Rare Dis. 2019. PMID: 30770754 Free PMC article. Review.
Cited by
-
Mass spectrometry techniques in the survey of steroid metabolites as potential disease biomarkers: a review.Metabolism. 2013 Sep;62(9):1206-17. doi: 10.1016/j.metabol.2013.04.003. Epub 2013 May 7. Metabolism. 2013. PMID: 23664145 Free PMC article. Review.
-
Design of novel Surfactant Modified Carbon Nanotube Paste Electrochemical Sensor for the Sensitive Investigation of Tyrosine as a Pharmaceutical Drug.Adv Pharm Bull. 2019 Feb;9(1):132-137. doi: 10.15171/apb.2019.016. Epub 2019 Feb 21. Adv Pharm Bull. 2019. PMID: 31011567 Free PMC article.
-
Manganese tetraphenylporphyrin and carbon nanocoil interface-based electrochemical sensing of tyrosine.RSC Adv. 2024 Aug 1;14(33):24105-24114. doi: 10.1039/d4ra02048k. eCollection 2024 Jul 26. RSC Adv. 2024. PMID: 39131187 Free PMC article.
-
Gold nanoparticle formation as an indicator of enzymatic methods: colorimetric L-phenylalanine determination.Anal Bioanal Chem. 2022 Mar;414(8):2641-2649. doi: 10.1007/s00216-022-03900-3. Epub 2022 Jan 21. Anal Bioanal Chem. 2022. PMID: 35064303 Free PMC article.
-
A voltammetric sensor based on reduced graphene oxide-hemin-Ag nanocomposites for sensitive determination of tyrosine.RSC Adv. 2020 Jul 28;10(47):28026-28031. doi: 10.1039/d0ra04976j. eCollection 2020 Jul 27. RSC Adv. 2020. PMID: 35519092 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous