An examination of physiological mechanisms underlying the frequency-doubling illusion
- PMID: 12407172
An examination of physiological mechanisms underlying the frequency-doubling illusion
Abstract
Purpose: The frequency-doubling illusion is an apparent doubling of spatial frequency when a sinusoidal grating is modulated rapidly in temporal counterphase. It has been proposed that the illusion arises from a spatially nonlinear ganglion cell class. The current study reexamines this possibility and investigates other mechanisms that may underlie the illusion.
Methods: Responses of macaque magnocellular (MC) retinal ganglion cells were recorded to counterphase-modulated sinusoidal gratings of various spatial frequencies, and linearity of spatial summation was assessed. Human psychophysical thresholds were measured for a variety of phase discrimination and matching tasks.
Results: Consistent with lateral geniculate recordings reported by other authors, no evidence was found of a separate nonlinear (M(y)) MC cell class. The small, spatially nonlinear responses found were least at the low spatial frequencies used in clinical testing. Further analysis showed that no spatially modulated signal can be expected from the nonlinear response of a ganglion cell; the nonlinearity of spatial summation gives a doubled response in time but not across space. Psychophysical performance was consistent with an inability to distinguish the temporal phase of counterphase-modulated gratings when the illusion occurs. From 4 to 40 Hz, the zero-crossings of the modulated sinusoidal grating provided a spatial cue and were matched to comparison patterns at twice the stimulus spatial frequency.
Conclusions: These results are inconsistent with the hypothesis that spatially nonlinear (M(y)) retinal ganglion cells are the physiological substrate of the frequency-doubling illusion. A cortical loss of temporal phase discrimination may be the principle cause of the illusion.
Similar articles
-
Perceived spatial frequency of sinusoidal gratings.Optom Vis Sci. 2008 May;85(5):318-29. doi: 10.1097/OPX.0b013e31816be9fd. Optom Vis Sci. 2008. PMID: 18451736
-
Nonlinear signal summation in magnocellular neurons of the macaque lateral geniculate nucleus.J Neurophysiol. 2009 Sep;102(3):1921-9. doi: 10.1152/jn.00331.2009. Epub 2009 Jul 8. J Neurophysiol. 2009. PMID: 19587318 Free PMC article.
-
The spatiotemporal precision of ganglion cell signals: a comparison of physiological and psychophysical performance with moving gratings.Vision Res. 2004 Jan;44(1):19-33. doi: 10.1016/j.visres.2003.08.017. Vision Res. 2004. PMID: 14599568
-
The Hermann grid illusion: a tool for studying human perspective field organization.Perception. 1994;23(6):691-708. doi: 10.1068/p230691. Perception. 1994. PMID: 7845762 Review.
-
Capabilities of monkey cortical cells in spatial-resolution tasks.J Opt Soc Am A. 1985 Jul;2(7):1101-14. doi: 10.1364/josaa.2.001101. J Opt Soc Am A. 1985. PMID: 3926970 Review.
Cited by
-
Spatial Frequency Shifts From Counterphase Flicker and From Simultaneous Contrast.Iperception. 2017 May 19;8(3):2041669517707766. doi: 10.1177/2041669517707766. eCollection 2017 May-Jun. Iperception. 2017. PMID: 28567269 Free PMC article.
-
Frequency-doubling technology and parasol cells.Invest Ophthalmol Vis Sci. 2011 Jun 1;52(6):3759; author reply 3759-60. doi: 10.1167/iovs.11-7405. Invest Ophthalmol Vis Sci. 2011. PMID: 21632705 Free PMC article. No abstract available.
-
Comparison of Humphrey Matrix frequency doubling technology to standard automated perimetry in neuro-ophthalmic disease.Middle East Afr J Ophthalmol. 2012 Apr-Jun;19(2):211-5. doi: 10.4103/0974-9233.95254. Middle East Afr J Ophthalmol. 2012. PMID: 22623861 Free PMC article.
-
Topography of the frequency doubling perimetry visual field compared with that of short wavelength and achromatic automated perimetry visual fields.Br J Ophthalmol. 2006 Jan;90(1):70-4. doi: 10.1136/bjo.2005.071266. Br J Ophthalmol. 2006. PMID: 16361671 Free PMC article. Clinical Trial.
-
Comparison of matrix frequency-doubling technology perimetry and standard automated perimetry in monitoring the development of visual field defects for glaucoma suspect eyes.PLoS One. 2017 May 18;12(5):e0178079. doi: 10.1371/journal.pone.0178079. eCollection 2017. PLoS One. 2017. PMID: 28542536 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources