Improved image quality and detection of acute cerebral infarction with PROPELLER diffusion-weighted MR imaging
- PMID: 12409594
- DOI: 10.1148/radiol.2252011479
Improved image quality and detection of acute cerebral infarction with PROPELLER diffusion-weighted MR imaging
Abstract
Purpose: To compare periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) multishot fast spin-echo diffusion-weighted magnetic resonance (MR) imaging with single-shot echo-planar diffusion-weighted MR imaging for image quality and visualization of acute cerebral infarction.
Materials and methods: Seventy subjects (35 men, 35 women; mean age, 55 years +/- 24 [SD]) who were suspected of having acute cerebral infarction (symptom duration, 2.8 days +/- 2.7) underwent PROPELLER and echo-planar MR imaging (b = 1,000 sec/mm(2)). Two neuroradiologists compared unlabeled images for presence of artifacts, visualization of infarction, and their preference of images. Interobserver agreement and image comparison were assessed by using the kappa statistic and the chi(2) test, respectively.
Results: PROPELLER MR imaging reduced susceptibility artifacts (n = 70 subjects), which limited visualization of temporal (echo-planar, n = 64; PROPELLER, n = 0; P <.01, chi(2) test), frontal (echo-planar, n = 58; PROPELLER, n = 1; P <.01), and parietal lobes (echo-planar, n = 5; PROPELLER, n = 0; P <.05) and cerebellum (echo-planar, n = 36; PROPELLER, n = 0; P <.01) and brainstem (echo-planar, n = 23; PROPELLER, n = 0; P <.01). Acute infarction (n = 31 subjects) was better demonstrated at PROPELLER MR imaging (PROPELLER better, n = 18; echo-planar better, n = 1; PROPELLER and echo-planar equal, n = 12; P <.01, chi(2) test). PROPELLER MR imaging was preferred in all (n = 70) but one case in which the lesion lay within the intersection gap (PROPELLER preferred, n = 69; echo-planar preferred, n = 1; P <.01, chi(2) test).
Conclusion: With a short increase in imaging time, PROPELLER MR imaging offers better image quality and detection of acute cerebral infarction than does echo-planar MR imaging.
Copyright RSNA, 2002
Similar articles
-
Salivary glands: echo-planar versus PROPELLER Diffusion-weighted MR imaging for assessment of ADCs.Radiology. 2009 Oct;253(1):144-52. doi: 10.1148/radiol.2531082228. Radiology. 2009. PMID: 19789257
-
Echoplanar MR imaging for ultrafast detection of brain lesions.AJR Am J Roentgenol. 1999 Aug;173(2):479-85. doi: 10.2214/ajr.173.2.10430158. AJR Am J Roentgenol. 1999. PMID: 10430158
-
Diffusion-weighted imaging in patients with acute brain ischemia at 3 T: current possibilities and future perspectives comparing conventional echoplanar diffusion-weighted imaging and fast spin echo diffusion-weighted imaging sequences using BLADE (PROPELLER).Invest Radiol. 2009 Jun;44(6):351-9. doi: 10.1097/RLI.0b013e3181a00d09. Invest Radiol. 2009. PMID: 19363447
-
Diffusion-weighted MR of the brain: methodology and clinical application.Radiol Med. 2005 Mar;109(3):155-97. Radiol Med. 2005. PMID: 15775887 Review. English, Italian.
-
[The clinical application of diffusion weighted magnetic resonance imaging to acute cerebrovascular disorders].No To Shinkei. 1998 Sep;50(9):787-95. No To Shinkei. 1998. PMID: 9789301 Review. Japanese.
Cited by
-
Diffusion tensor MR imaging and fiber tractography: technical considerations.AJNR Am J Neuroradiol. 2008 May;29(5):843-52. doi: 10.3174/ajnr.A1052. Epub 2008 Mar 13. AJNR Am J Neuroradiol. 2008. PMID: 18339719 Free PMC article. Review.
-
Differentiation between Graves' disease and painless thyroiditis by diffusion-weighted imaging, thyroid iodine uptake, thyroid scintigraphy and serum parameters.Exp Ther Med. 2015 Jun;9(6):2165-2172. doi: 10.3892/etm.2015.2430. Epub 2015 Apr 17. Exp Ther Med. 2015. PMID: 26136954 Free PMC article.
-
Improving image quality using the pause function combination to PROPELLER sequence in brain MRI: a phantom study.Radiol Phys Technol. 2024 Jun;17(2):518-526. doi: 10.1007/s12194-024-00784-z. Epub 2024 Feb 17. Radiol Phys Technol. 2024. PMID: 38367143
-
Influence of blade width and magnetic field strength on the ADC on PROPELLER DWI in head and neck.Neuroradiol J. 2020 Feb;33(1):39-47. doi: 10.1177/1971400919870178. Epub 2019 Aug 13. Neuroradiol J. 2020. PMID: 31407966 Free PMC article.
-
PROPELLER EPI: an MRI technique suitable for diffusion tensor imaging at high field strength with reduced geometric distortions.Magn Reson Med. 2005 Nov;54(5):1232-40. doi: 10.1002/mrm.20677. Magn Reson Med. 2005. PMID: 16206142 Free PMC article.