Measurement of heterogeneous distribution on Technegas SPECT images by three-dimensional fractal analysis
- PMID: 12416574
- DOI: 10.1007/BF02990073
Measurement of heterogeneous distribution on Technegas SPECT images by three-dimensional fractal analysis
Abstract
This review article describes a method for quantifying heterogeneous distribution on Technegas (99mTc-carbon particle radioaerosol) SPECT images by three-dimensional fractal analysis (3D-FA). Technegas SPECT was performed to quantify the severity of pulmonary emphysema. We delineated the SPECT images by using five cut-offs (15, 20, 25, 30 and 35% of the maximal voxel radioactivity), and measured the total number of voxels in the areas surrounded by the contours obtained with each cut-off level. We calculated fractal dimensions from the relationship between the total number of voxels and the cut-off levels transformed into natural logarithms. The fractal dimension derived from 3D-FA is the relative and objective measurement, which can assess the heterogeneous distribution on Technegas SPECT images. The fractal dimension strongly correlate pulmonary function in patients with emphysema and well documented the overall and regional severity of emphysema.
Similar articles
-
Quantitative analysis of technegas SPECT: evaluation of regional severity of emphysema.J Nucl Med. 2000 Apr;41(4):590-5. J Nucl Med. 2000. PMID: 10768557
-
Quantitative analysis of pulmonary emphysema: three-dimensional fractal analysis of single-photon emission computed tomography images obtained with a carbon particle radioaerosol.AJR Am J Roentgenol. 1998 Dec;171(6):1657-63. doi: 10.2214/ajr.171.6.9843308. AJR Am J Roentgenol. 1998. PMID: 9843308
-
A stripe sign on 99mTc-Technegas SPECT in pulmonary emphysema.Nucl Med Commun. 2008 Jun;29(6):553-61. doi: 10.1097/MNM.0b013e3282f57f8b. Nucl Med Commun. 2008. PMID: 18458603
-
[99mTc-Technegas].Nihon Igaku Hoshasen Gakkai Zasshi. 2000 Apr;60(5):243-8. Nihon Igaku Hoshasen Gakkai Zasshi. 2000. PMID: 10824531 Review. Japanese.
-
Technical and analytical advances in pulmonary ventilation SPECT with xenon-133 gas and Tc-99m-Technegas.Ann Nucl Med. 2002 Jul;16(5):303-10. doi: 10.1007/BF02988614. Ann Nucl Med. 2002. PMID: 12230089 Review.
Cited by
-
Longitudinal study of COPD phenotypes using integrated SPECT and qCT imaging.Front Physiol. 2025 Apr 25;16:1555230. doi: 10.3389/fphys.2025.1555230. eCollection 2025. Front Physiol. 2025. PMID: 40352142 Free PMC article.
-
Two decades of SPECT/CT - the coming of age of a technology: An updated review of literature evidence.Eur J Nucl Med Mol Imaging. 2019 Sep;46(10):1990-2012. doi: 10.1007/s00259-019-04404-6. Epub 2019 Jul 4. Eur J Nucl Med Mol Imaging. 2019. PMID: 31273437 Free PMC article. Review.
-
Radiomics-based differentiation of lung disease models generated by polluted air based on X-ray computed tomography data.BMC Med Imaging. 2016 Feb 11;16:14. doi: 10.1186/s12880-016-0118-z. BMC Med Imaging. 2016. PMID: 26864653 Free PMC article.
-
Regional cerebral blood flow single photon emission computed tomography for detection of Frontotemporal dementia in people with suspected dementia.Cochrane Database Syst Rev. 2015 Jun 23;2015(6):CD010896. doi: 10.1002/14651858.CD010896.pub2. Cochrane Database Syst Rev. 2015. PMID: 26102272 Free PMC article.
-
Techniques of assessing small airways dysfunction.Eur Clin Respir J. 2014 Oct 17;1. doi: 10.3402/ecrj.v1.25898. eCollection 2014. Eur Clin Respir J. 2014. PMID: 26557240 Free PMC article. Review.