Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2002;32(14):879-85.
doi: 10.2165/00007256-200232140-00001.

Core temperature measurement: methods and current insights

Affiliations
Review

Core temperature measurement: methods and current insights

Daniel S Moran et al. Sports Med. 2002.

Abstract

Climatic injuries, including hypothermia, hyperthermia and heat stroke, are common in many sports activities. Body core temperature (T(c)) measurement for the sportsperson can influence individual performance and may help to prevent injuries. Monitoring internal body T(c) accurately requires invasive methods of measurement. The mercury thermometer, most commonly used to measure oral temperature (T(oral)), has been almost exclusively the only instrument for measuring T(c) since the 18th century. Rectal (T(re)) and oesophageal temperatures (T(oes)) have been the most preferred measurement sites employed in thermoregulatory investigations. However, these measurement sites (T(re), T(oes), T(oral)), and the methods used to measure T(c) at these sites, are not convenient. T(oral) measurements are not always possible or accurate. T(oes) is undesirable because of the difficulty of inserting the thermistor, irritation to nasal passages and general subject discomfort. T(re) is not suitable under many circumstances as it is labour intensive and has a prolonged response time. However, T(re) remains the most accurately available method for monitoring T(c) in thermal illness that occurs during sports activities. In addition, T(re) and T(oes) require wire connections between the thermistor and the monitoring device. The purpose of this paper is to review the various existing methods of T(c) measurements in order to focus on the breakthrough needed for a simple, noninvasive, universally used device for T(c) measurement which is essential for preventing climatic injuries during sports events.

PubMed Disclaimer

References

    1. Anesth Analg. 2000 Apr;90(4):938-45 - PubMed
    1. JAMA. 1996 Jul 17;276(3):194 - PubMed
    1. Chest. 1999 Apr;115(4):1002-5 - PubMed
    1. IEEE Eng Med Biol Mag. 1998 Jul-Aug;17(4):19-24 - PubMed
    1. South Med J. 1996 Feb;89(2):230-4 - PubMed

LinkOut - more resources