Corneal flap displacement and drift in LASIK: comparison of Hansatome and Automated Corneal Shaper microkeratomes
- PMID: 12429246
- DOI: 10.1016/s0002-9394(02)01675-6
Corneal flap displacement and drift in LASIK: comparison of Hansatome and Automated Corneal Shaper microkeratomes
Abstract
Purpose: To describe and compare the displacement of corneal flaps created during laser in situ keratomileusis (LASIK) procedures performed with two different microkeratomes and analyze parameters (for example, pupil-to-hinge distance, drift during suction) that might affect the flap displacement or be influenced by flap displacement.
Design: This work was based on a cross-sectional study design.
Methods: Images copied from video recordings of 206 consecutive LASIK surgeries were analyzed to determine the distance from pupil center to corneal flap hinge (pupil-to-hinge distance), the hinge size, the distance from the center of the pupil to the margins of the flap, and the positions of the suction ring before and after vacuum in corneal flaps created by the Hansatome and the Automated Corneal Shaper (ACS) microkeratomes. Accurate measurements of all these variables could be obtained in 121 eyes (Hansatome: n = 66, right eye (OD) = 27 eyes, left eye (OS) = 39 eyes; ACS: n = 55, OD = 25 eyes, OS = 30 eyes), which were included in the analysis. Formulas were derived to calculate from the measurements the magnitude and direction of the drift of the suction ring during vacuum and the final displacement of the corneal flap.
Results: The mean +/- standard deviation (SD) drift of eyes during suction with the Hansatome was 0.27 +/- 0.02 mm and with the ACS was 0.12 +/- 0.02 mm (P <.001). The Hansatome induced, on average, more biased (temporal vs random) drift than did the ACS. The mean final displacement of the center of the flap from the center of the pupil was of equal magnitude for the two instruments (0.37 +/- 0.02 mm and 0.36 +/- 0.02 mm with the Hansatome and ACS, respectively).
Conclusion: The drift induced by the Hansatome contributes to the horizontal component of the final decentration of the corneal flaps. This tendency for drift and the resultant decrease in pupil-to-hinge distance should be considered to minimize flap displacements during LASIK.
Similar articles
-
Predictability of corneal flap thickness in laser in situ keratomileusis using three different microkeratomes.J Refract Surg. 2002 May-Jun;18(3 Suppl):S347-51. doi: 10.3928/1081-597X-20020502-13. J Refract Surg. 2002. PMID: 12046880
-
Laser in situ keratomileusis flap thickness using the Hansatome microkeratome with zero compression heads.J Cataract Refract Surg. 2006 Jan;32(1):72-7. doi: 10.1016/j.jcrs.2005.07.042. J Cataract Refract Surg. 2006. PMID: 16516782 Clinical Trial.
-
Incidence of intraoperative flap complications in laser in situ keratomileusis.J Cataract Refract Surg. 2002 Jan;28(1):23-8. doi: 10.1016/s0886-3350(01)01097-5. J Cataract Refract Surg. 2002. PMID: 11777706
-
Flap and interface complications in LASIK.Curr Opin Ophthalmol. 2002 Aug;13(4):242-5. doi: 10.1097/00055735-200208000-00010. Curr Opin Ophthalmol. 2002. PMID: 12165708 Review.
-
Risk factors and visual results in cases of LASIK flap repositioning due to folds or dislocation: case series and literature review.Int Ophthalmol. 2014 Feb;34(1):19-26. doi: 10.1007/s10792-013-9776-9. Epub 2013 Apr 19. Int Ophthalmol. 2014. PMID: 23605593 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources