Diagnosis of prosthetic mitral valve malfunction with combined echo-phonocardiography
- PMID: 1244259
- DOI: 10.1161/01.cir.53.1.93
Diagnosis of prosthetic mitral valve malfunction with combined echo-phonocardiography
Abstract
Fifty-three patients were studied with combined echo-phonocardiography or phonocardiography alone following prosthetic valve replacement. In sixteen of these patients, clinical deterioration developed, and all subsequently underwent cardiac catheterization and/or surgery. Two patients came to autopsy. Included in this group of sixteen patients were five with obstructed prosthesis, six with paravalvular regurgitation, and five with left ventricular dysfunction. Measurements were made of the time interval from the aortic valve closure sound to the peak opening of the mitral prosthesis determined echocardiographically or to the mitral prosthetic opening click (A2-MVO). Echocardiographic studies of left ventricular wall motion were also performed. The A2-MVO interval was significantly shortened (P less than 0.01) with prosthetic valve obstruction (.05 +/- .02 sec) and paravalvular regurgitation (.05 +/- .01 sec) compared with normally functioning prostheses (Starr-Edwards ball valves .10 +/- .02 sec, Lillehei-Kaster tilting disc prostheses .09 +/- .01 sec). Shortening of this interval was not specific for these conditions because it was sometimes shortened with left ventricular dysfunction. Echocardiographic studies of left ventricular wall motion were helpful in distinguishing among prosthetic valve obstruction, paravalvular regurgitation and left ventricular dysfunction. The combined echo-phonocardiographic technique was especially helpful in detecting malfunction of tilting disc prostheses, because the technique enables measurement of the A2-MVO interval in the absence of an audible opening click.
Similar articles
-
Echo-phonocardiographic evaluation of the Björk-Shiley mitral prosthesis.Am J Cardiol. 1986 Jan 1;57(1):165-70. doi: 10.1016/0002-9149(86)90973-2. Am J Cardiol. 1986. PMID: 3942063
-
Left ventricular dysfunction versus paravalvular leak in patients with mitral disc prostheses.Acta Cardiol. 1986;41(3):179-83. Acta Cardiol. 1986. PMID: 3490083
-
[Echocardiographic diagnosis of malfunction of the Björk-Shiley prosthetic heart valve in the mitral position (author's transl)].Z Kardiol. 1979 Jan;68(1):21-5. Z Kardiol. 1979. PMID: 419805 German.
-
Ultrasonography of prosthetic cardiac valves.Crit Rev Diagn Imaging. 1981;14(3):243-79. Crit Rev Diagn Imaging. 1981. PMID: 7014103 Review.
-
Current status of the Beall, Bjork-Shiley, Braunwald-Cutter, Lillehei-Kaster and Smeloff-Cutter cardiac valve prostheses.Am J Cardiol. 1975 Jun;35(6):855-65. doi: 10.1016/0002-9149(75)90122-8. Am J Cardiol. 1975. PMID: 124127 Review.
Cited by
-
Noninvasive assessment of the Ionescu-Shiley pericardial xenograft in the mitral position: preliminary experience.Tex Heart Inst J. 1982 Sep;9(3):275-84. Tex Heart Inst J. 1982. PMID: 15226927 Free PMC article.
-
Echocardiography after reconstructive surgery for non-rheumatic mitral regurgitation.Br Heart J. 1977 Dec;39(12):1299-306. doi: 10.1136/hrt.39.12.1299. Br Heart J. 1977. PMID: 603730 Free PMC article. No abstract available.
-
Bioengineering aspects of heart valve replacement.Ann Biomed Eng. 1982;10(3):97-128. doi: 10.1007/BF02367460. Ann Biomed Eng. 1982. PMID: 6763846 Review.
-
Fibrinolytic treatment of thrombus on prosthetic heart valves.Br Heart J. 1980 Nov;44(5):545-54. doi: 10.1136/hrt.44.5.545. Br Heart J. 1980. PMID: 7437196 Free PMC article.
-
Echophonocardiography in diagnosis of mitral paravalvular regurgitation with Björk-Shiley prosthetic valve.Br Heart J. 1980 Mar;43(3):325-31. doi: 10.1136/hrt.43.3.325. Br Heart J. 1980. PMID: 7437180 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources