Upper-extremity volume measurements in women with lymphedema: a comparison of measurements obtained via water displacement with geometrically determined volume
- PMID: 12444879
Upper-extremity volume measurements in women with lymphedema: a comparison of measurements obtained via water displacement with geometrically determined volume
Abstract
Background and purpose: Upper-extremity (UE) swelling following breast cancer treatment is a frequent manifestation of lymphedema. In order to document outcomes from lymphedema treatments, reliable, valid, and practical measurements of UE swelling are necessary. The purpose of this study was to compare geometric methods of determining UE volumes with water displacement methods.
Subjects: The edematous hand, forearm, and upper arm of 50 women with UE swelling secondary to lymphedema were measured.
Methods: Upper-extremity volumes were determined by water displacement using arm and hand volumeters. Displaced water was weighed to determine volume. Circumferential girth measurements were taken. Width and depth measurements of the hand were taken with a tension-controlled caliper. Geometric volume formulas for a cylinder, frustum, rectangular solid, and trapezoidal solid were used to calculate volumes of the arm and hand at different measurement intervals.
Results: Intraclass correlation coefficients [2,1] for interrater and intrarater reliability of all water and geometric measurements of the arm and hand were.91 to.99 and.92 to.99, respectively. Water displacement correlated with geometric measurements in the arm (r=.97-.98) and in the hand (r=.81-.91). The limits of agreement (LOA) indicated that water and geometric measurements of arm volume differed by 479 to 655 mL. Scatterplots of the LOA data indicated in that geometric volumes were either larger or smaller than water volumes. The smallest standard error of measurement for the arm measurements was for the 6-cm frustum method at 115 mL; for the hand measurements, the smallest standard error of measurement was for the frustum method at 16 mL.
Discussion and conclusion: Volume of an edematous UE calculated by geometric formulas correlated strongly with volume determined by water displacement. Although strongly correlated, the measurements obtained by the 2 methods did not agree.
Similar articles
-
Reliability and validity of arm volume measurements for assessment of lymphedema.Phys Ther. 2006 Feb;86(2):205-14. Phys Ther. 2006. PMID: 16445334
-
Reliability and limits of agreement of circumferential, water displacement, and optoelectronic volumetry in the measurement of upper limb lymphedema.Lymphology. 2007 Mar;40(1):26-34. Lymphology. 2007. PMID: 17539462
-
Concurrent validity of upper-extremity volume estimates: comparison of calculated volume derived from girth measurements and water displacement volume.Phys Ther. 2003 Feb;83(2):134-45. Phys Ther. 2003. PMID: 12564949
-
A clinically useful method for evaluating lymphedema.Clin J Oncol Nurs. 2004 Feb;8(1):35-8. doi: 10.1188/04.CJON.35-38. Clin J Oncol Nurs. 2004. PMID: 14983761 Review.
-
[Volumetrics: an indispensable complementary test in lymphology].Rev Med Interne. 2002 Jun;23 Suppl 3:388s-390s. doi: 10.1016/s0248-8663(02)80380-0. Rev Med Interne. 2002. PMID: 12162201 Review. French.
Cited by
-
Current diagnostic and quantitative techniques in the field of lymphedema management: a critical review.Med Oncol. 2024 Sep 5;41(10):241. doi: 10.1007/s12032-024-02472-9. Med Oncol. 2024. PMID: 39235664 Free PMC article. Review.
-
Complete Reduction of Leg Lymphedema after Liposuction: A 5-Year Prospective Study in 67 Patients without Recurrence.Plast Reconstr Surg Glob Open. 2023 Dec 7;11(12):e5429. doi: 10.1097/GOX.0000000000005429. eCollection 2023 Dec. Plast Reconstr Surg Glob Open. 2023. PMID: 38074499 Free PMC article.
-
Comprehensive strategies in breast cancer-related lymphedema prevention: insights from a multifaceted program.Front Oncol. 2024 Jul 16;14:1418610. doi: 10.3389/fonc.2024.1418610. eCollection 2024. Front Oncol. 2024. PMID: 39081716 Free PMC article.
-
Establishing regions of interest of the lower leg and ankle for perioperative volumetric assessment with a portable 3D scanner in orthopedic and trauma surgery - a pilot study.J Foot Ankle Res. 2023 Dec 5;16(1):87. doi: 10.1186/s13047-023-00684-2. J Foot Ankle Res. 2023. PMID: 38049875 Free PMC article.
-
The addition of self-lymphatic drainage to compression therapy instead of manual lymphatic drainage in the first phase of complex decongestive therapy for treatment of breast cancer-related lymphedema: A randomized-controlled, prospective study.Turk J Phys Med Rehabil. 2018 Dec 21;65(4):309-317. doi: 10.5606/tftrd.2019.3126. eCollection 2019 Jun. Turk J Phys Med Rehabil. 2018. PMID: 31893267 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Other Literature Sources
Medical