Distal filter protection during saphenous vein graft stenting: technical and clinical correlates of efficacy
Abstract
Objectives: The aim of this study was to evaluate the clinical, angiographic, and technical factors related to successful stenting of diseased saphenous vein grafts (SVGs) using a novel filter-based distal protection device.
Background: Protection of the distal microvasculature with a balloon occlusion and aspiration system has been shown to reduce atherothrombotic embolization and peri-procedural myocardial infarction (MI) after percutaneous coronary intervention (PCI) in SVGs. The safety, efficacy, and technical factors relating to procedural success with filter-based distal protection devices are unknown.
Methods: Percutaneous coronary intervention was performed in 60 lesions in 48 patients undergoing SVG intervention with the FilterWire EX distal protection system in a phase I experience at six sites. A larger phase II study was then performed in 248 lesions in 230 SVGs at 65 U.S. centers.
Results: Cumulative adverse events to 30 days occurred in 21.3% of patients in phase I, including a 19.1% rate of MI. Numerous anatomic, device-specific, and operator-related contributors to these adverse events were identified, resulting in significant changes to the protocol and instructions for use. Subsequently, despite similar clinical and angiographic characteristics to the phase I patients, the 30-day adverse event rate in phase II was reduced to 11.3% (p = 0.09), due primarily to a lower incidence of peri-procedural Q-wave and non-Q-wave MI.
Conclusions: Distal protection during SVG PCI with the FilterWire EX is associated with a low rate of peri-procedural adverse events compared to historical controls. A unique set of anatomic, technical, and operator-related issues exist with distal filters which, if ignored, may reduce their effectiveness.
Similar articles
-
A novel filter-based distal embolic protection device for percutaneous intervention of saphenous vein graft lesions: results of the AMEthyst randomized controlled trial.JACC Cardiovasc Interv. 2008 Jun;1(3):248-57. doi: 10.1016/j.jcin.2008.03.009. JACC Cardiovasc Interv. 2008. PMID: 19463308 Clinical Trial.
-
Randomized comparison of distal protection with a filter-based catheter and a balloon occlusion and aspiration system during percutaneous intervention of diseased saphenous vein aorto-coronary bypass grafts.Circulation. 2003 Aug 5;108(5):548-53. doi: 10.1161/01.CIR.0000080894.51311.0A. Epub 2003 Jul 21. Circulation. 2003. PMID: 12874191 Clinical Trial.
-
Distal filter protection during percutaneous coronary intervention in native coronary arteries and saphenous vein grafts in patients with acute coronary syndromes.Ital Heart J. 2003 Sep;4(9):614-9. Ital Heart J. 2003. PMID: 14635379
-
Mechanical protection of cardiac microcirculation during percutaneous coronary intervention of saphenous vein grafts.Int J Cardiol. 2005 Mar 30;99(3):365-72. doi: 10.1016/j.ijcard.2004.05.036. Int J Cardiol. 2005. PMID: 15771915 Review.
-
Embolic protection devices in saphenous percutaneous intervention.EuroIntervention. 2009 May;5 Suppl D:D45-50. EuroIntervention. 2009. PMID: 19736070 Review.
Cited by
-
Embolic protection devices.Heart. 2003 Sep;89(9):990-2. doi: 10.1136/heart.89.9.990. Heart. 2003. PMID: 12923006 Free PMC article. No abstract available.
-
Distal embolic protection during renal artery stenting: impact on hypertensive patients with renal dysfunction.J Clin Hypertens (Greenwich). 2008 Nov;10(11):830-6. doi: 10.1111/j.1751-7176.2008.00030.x. J Clin Hypertens (Greenwich). 2008. PMID: 19128271 Free PMC article.
-
Recent publications by ochsner authors.Ochsner J. 2003 Spring;5(2):57-62. Ochsner J. 2003. PMID: 21765756 Free PMC article. No abstract available.
Publication types