Comparison of image quality obtained with optical and radiographic magnification techniques in fine-detail skeletal radiography: effect of object thickness
- PMID: 1244657
- DOI: 10.1148/118.1.189
Comparison of image quality obtained with optical and radiographic magnification techniques in fine-detail skeletal radiography: effect of object thickness
Abstract
High-resolution radiography may be done using either optical or radiographic magnification. In the former technique, industrial Type M film was used without screens and the image was viewed with 4-10X optical magnification. In the latter technique, RP film was used with Detail screens and 4X geometric magnification together with a microfocus x-ray tube having a nominal focal spot size of 50 mum. The imaging properties of both techniques were evaluated by means of H & D curves, modulation transfer functions, and Wiener spectra. It was found that for thin objects such as the hand, optical magnification provides better bone images than radiographic magnification; whereas for thicker parts such as the knee, radiographic magnification is superior.
Similar articles
-
Optical versus radiographic magnification for fine-detail skeletal radiography.Invest Radiol. 1975 Mar-Apr;10(2):160-72. doi: 10.1097/00004424-197503000-00010. Invest Radiol. 1975. PMID: 46857
-
Effect of film graininess and geometric unsharpness on image quality in fine-detail skeletal radiography.Invest Radiol. 1975 Jan-Feb;10(1):35-42. doi: 10.1097/00004424-197501000-00005. Invest Radiol. 1975. PMID: 1112648
-
[Direct radiological magnification of thin objects compared with contact exposures and mammographic techniques (author's transl)].Rofo. 1982 Apr;136(4):453-62. doi: 10.1055/s-2008-1056081. Rofo. 1982. PMID: 6212485 German.
-
[Direct radiographic magnification in combination with digital radiography for bone imaging].Radiologe. 1991 Sep;31(9):424-9. Radiologe. 1991. PMID: 1947061 Review. German.
-
High-resolution skeletal radiography: image quality and clinical applications.Curr Probl Diagn Radiol. 1978 Jan-Feb;7(7):1-62. Curr Probl Diagn Radiol. 1978. PMID: 343997 Review. No abstract available.
Cited by
-
High-resolution ultrasonography of the first metatarsal phalangeal joint in gout: a controlled study.Ann Rheum Dis. 2007 Jul;66(7):859-64. doi: 10.1136/ard.2006.062802. Epub 2006 Dec 21. Ann Rheum Dis. 2007. PMID: 17185326 Free PMC article.
-
Evaluation of magnification radiography in bone tumors.Arch Orthop Trauma Surg (1978). 1980;97(2):107-10. doi: 10.1007/BF00450932. Arch Orthop Trauma Surg (1978). 1980. PMID: 7458595
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources