[The three-dimensional spiral scanner and volume rendering technique: importance in craniofacial traumatology and reconstructive surgery]
- PMID: 12451333
[The three-dimensional spiral scanner and volume rendering technique: importance in craniofacial traumatology and reconstructive surgery]
Abstract
There are two reconstruction methods for 3D imaging with a helical scanner: a surface rendering process providing a 3D-SSD (Surface Shaded Display) image that looks like a plaster cast skull and 3D-VRD (Volume Rendering Technique) which is more precise and gives 3D images similar to radiographs. We review briefly the techniques used to acquire these images and present 3D volume-rendering scanners, pointing out its usefulness in craniomaxillofacial traumatology and reconstructive surgery.
Similar articles
-
[Diagnostic value of multi-slice spiral CT three dimensional reconstruction in maxillofacial diseases].Zhongguo Yi Xue Ke Xue Yuan Xue Bao. 2006 Feb;28(1):16-20. Zhongguo Yi Xue Ke Xue Yuan Xue Bao. 2006. PMID: 16548181 Chinese.
-
[The value of three-dimensional helical CT imaging in the diagnosis of maxillofacial fractures].Hua Xi Yi Ke Da Xue Xue Bao. 2001 Mar;32(1):123-5. Hua Xi Yi Ke Da Xue Xue Bao. 2001. PMID: 12733376 Chinese.
-
[Evaluation of the accuracy of 3-D spiral CT in diagnosis of maxillofacial fracture].Shanghai Kou Qiang Yi Xue. 2007 Feb;16(1):100-3. Shanghai Kou Qiang Yi Xue. 2007. PMID: 17377713 Chinese.
-
Computer-aided surgery using 3D rendering of maxillofacial pathology and trauma.Int J Med Robot. 2007 Sep;3(3):203-6. doi: 10.1002/rcs.137. Int J Med Robot. 2007. PMID: 17592824 Review.
-
[CT].Nihon Rinsho. 2004 Apr;62(4):627-38. Nihon Rinsho. 2004. PMID: 15106335 Review. Japanese.
Cited by
-
[Interobserver variation of the sonographic diagnosis of orbital floor fractures and fractures of the infraorbital margin].Mund Kiefer Gesichtschir. 2004 Nov;8(6):337-43. doi: 10.1007/s10006-004-0571-7. Epub 2004 Oct 21. Mund Kiefer Gesichtschir. 2004. PMID: 15503239 German.
-
[Imaging diagnosis of medial and lateral orbital wall fractures. Sonography versus computed tomography].Mund Kiefer Gesichtschir. 2003 Jul;7(4):208-13. doi: 10.1007/s10006-003-0477-9. Epub 2003 May 20. Mund Kiefer Gesichtschir. 2003. PMID: 12961070 German.
-
A comparable study of the diagnostic performance of orbital ultrasonography and CBCT in patients with suspected orbital floor fractures.Dentomaxillofac Radiol. 2016 Jul;45(6):20150311. doi: 10.1259/dmfr.20150311. Epub 2016 May 4. Dentomaxillofac Radiol. 2016. PMID: 27074346 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous