Clinical Trial
. 2002 Nov-Dec;4(6):405-7, 412.
doi: 10.1111/j.1524-6175.2002.00953.x.

To what extent can we trust home blood pressure measurement? A randomized, controlled trial

Affiliations
Clinical Trial

To what extent can we trust home blood pressure measurement? A randomized, controlled trial

Lucas M Bachmann et al. J Clin Hypertens (Greenwich). 2002 Nov-Dec.

Abstract

Increasingly, patients measure and record their home blood pressure. However, the accuracy with which they report their readings to their physicians is largely unknown. The authors assessed the accuracy and quality of self-reported home blood pressure values in an ambulatory managed care population. Forty-eight hypertensive outpatients were randomly allocated to either receive information about the storage capabilities of a home blood pressure measuring device or not to receive such information. All patients were asked to record the measurement results in a logbook twice daily over a 7-day period. The main outcome measure was the difference in the number of fictional or manipulated reports per group and the difference in missing values. The combined parameter manipulated or fictional registrations occurred significantly less frequently in the informed group than in the noninformed group. (10/728 vs. 29/616; relative risk, 0.292; 95% confidence interval, 0.15-0.57; Pearson chi squared=13.15; p<0.0001). Informed patients had fewer missing registrations than the noninformed (13/728 vs. 41/616 measurements; relative risk, 0.27; 95% confidence interval, 0.15-0.47; Pearson chi squared =20.5; p<0.0001). The mean of the fictional data did not differ systematically from the mean of the correctly reported individual blood pressure values. There was no trend to over- or underestimate blood pressure values in the noninformed group. With this study design, it was possible to identify manipulation of home blood pressure values for the first time. Accuracy and interpretation of home blood pressure measurement may be increased by using devices with a memory function.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Mengden T, Hernandez Medina RM, et al. Reliability of reporting self‐measured blood pressure values by hypertensive patients. Am J Hypertens. 1998;11(12): 1413–1417. - PubMed
    1. Nordmann A, Frach B, Walker T, et al. Reliability of patients measuring blood pressure at home: prospective observational study. BMJ. 1999;319(7218):1172. - PMC - PubMed
    1. Stergiou GS, Malakos JS, Voutsa AV, et al. Home monitoring of blood pressure: limited value in general practice. J Hum Hypertens. 1996;10(4):219–223. - PubMed
    1. Merrick RD, Olive KE, Hamdy RC, et al. Factors influencing the accuracy of home blood pressure measurement. South Med J. 1997;90(11):1110–1114. - PubMed
    1. Johnson KA, Partsch DJ, Rippole LL, et al. Reliability of self‐reported blood pressure measurements. Arch Intern Med. 1999;159(22):2689–2693. - PubMed

Publication types