To what extent can we trust home blood pressure measurement? A randomized, controlled trial
- PMID: 12461302
- PMCID: PMC8101837
- DOI: 10.1111/j.1524-6175.2002.00953.x
To what extent can we trust home blood pressure measurement? A randomized, controlled trial
Abstract
Increasingly, patients measure and record their home blood pressure. However, the accuracy with which they report their readings to their physicians is largely unknown. The authors assessed the accuracy and quality of self-reported home blood pressure values in an ambulatory managed care population. Forty-eight hypertensive outpatients were randomly allocated to either receive information about the storage capabilities of a home blood pressure measuring device or not to receive such information. All patients were asked to record the measurement results in a logbook twice daily over a 7-day period. The main outcome measure was the difference in the number of fictional or manipulated reports per group and the difference in missing values. The combined parameter manipulated or fictional registrations occurred significantly less frequently in the informed group than in the noninformed group. (10/728 vs. 29/616; relative risk, 0.292; 95% confidence interval, 0.15-0.57; Pearson chi squared=13.15; p<0.0001). Informed patients had fewer missing registrations than the noninformed (13/728 vs. 41/616 measurements; relative risk, 0.27; 95% confidence interval, 0.15-0.47; Pearson chi squared =20.5; p<0.0001). The mean of the fictional data did not differ systematically from the mean of the correctly reported individual blood pressure values. There was no trend to over- or underestimate blood pressure values in the noninformed group. With this study design, it was possible to identify manipulation of home blood pressure values for the first time. Accuracy and interpretation of home blood pressure measurement may be increased by using devices with a memory function.
Copyright 2002 Le Jacq Communications, Inc.
Similar articles
-
[Manipulation of blood pressure self-monitoring protocol values: a randomized controlled study].Praxis (Bern 1994). 2003 Jun 4;92(23):1075-80. doi: 10.1024/0369-8394.92.23.1075. Praxis (Bern 1994). 2003. PMID: 12830671 Clinical Trial. German.
-
Self-measurement of blood pressure at home in the management of hypertension.Clin Med Res. 2005 Feb;3(1):19-26. doi: 10.3121/cmr.3.1.19. Clin Med Res. 2005. PMID: 15962017 Free PMC article. Review.
-
Home blood pressure self-monitoring: diagnostic performance in white-coat hypertension.Blood Press Monit. 2006 Apr;11(2):47-52. doi: 10.1097/01.mbp.0000200479.19046.94. Blood Press Monit. 2006. PMID: 16534404
-
Poor adherence to home blood pressure measurement schedule.J Hypertens. 2009 Feb;27(2):275-9. doi: 10.1097/hjh.0b013e328319917e. J Hypertens. 2009. PMID: 19226698
-
User procedure for self-measurement of blood pressure. First International Consensus Conference on Self Blood Pressure Measurement.Blood Press Monit. 2000 Apr;5(2):111-29. Blood Press Monit. 2000. PMID: 10828898 Review.
Cited by
-
When tight blood pressure control is not for everyone: a new model for performance measurement in hypertension.Jt Comm J Qual Patient Saf. 2010 Apr;36(4):164-72. doi: 10.1016/s1553-7250(10)36028-4. Jt Comm J Qual Patient Saf. 2010. PMID: 20402373 Free PMC article.
-
Considering the inclusion of metabolic and cardiovascular markers in the Panel Study of Income Dynamics.Biodemography Soc Biol. 2009;55(2):140-58. doi: 10.1080/19485560903382437. Biodemography Soc Biol. 2009. PMID: 20183902 Free PMC article. Review.
-
Practical advice for home blood pressure measurement.Can J Cardiol. 2007 May 15;23(7):577-80. doi: 10.1016/s0828-282x(07)70804-8. Can J Cardiol. 2007. PMID: 17534466 Free PMC article. Review.
-
Reliability of morning, before-dinner, and at-bedtime home blood pressure measurements in patients with hypertension.J Clin Hypertens (Greenwich). 2018 Feb;20(2):315-323. doi: 10.1111/jch.13165. Epub 2018 Jan 6. J Clin Hypertens (Greenwich). 2018. PMID: 29316183 Free PMC article.
-
The Association of Health Literacy with High-Quality Home Blood Pressure Monitoring for Hypertensive Patients in Outpatient Settings.Int J Hypertens. 2020 Mar 31;2020:7502468. doi: 10.1155/2020/7502468. eCollection 2020. Int J Hypertens. 2020. PMID: 32292599 Free PMC article. Review.
References
-
- Mengden T, Hernandez Medina RM, et al. Reliability of reporting self‐measured blood pressure values by hypertensive patients. Am J Hypertens. 1998;11(12): 1413–1417. - PubMed
-
- Stergiou GS, Malakos JS, Voutsa AV, et al. Home monitoring of blood pressure: limited value in general practice. J Hum Hypertens. 1996;10(4):219–223. - PubMed
-
- Merrick RD, Olive KE, Hamdy RC, et al. Factors influencing the accuracy of home blood pressure measurement. South Med J. 1997;90(11):1110–1114. - PubMed
-
- Johnson KA, Partsch DJ, Rippole LL, et al. Reliability of self‐reported blood pressure measurements. Arch Intern Med. 1999;159(22):2689–2693. - PubMed
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical