Abstract
Objective: The purpose of this document is to summarize and evaluate the effectiveness of new automated perimetry tests and algorithms in diagnosing glaucoma and detecting disease progression.
Methods: A literature search on automated perimetry retrieved over 300 citations from 1994 to 2001, of which 71 were selected as relevant to this assessment. The quality of the evidence obtained from these studies was assessed by the methodologist.
Results: The four automated perimetry techniques described in this assessment are short wavelength automated perimetry (SWAP), frequency doubling technology perimetry (FDT), high-pass resolution perimetry (HPRP), and motion automated perimetry (MAP). The algorithms described are Swedish interactive threshold algorithm (SITA) and SITA fast. With the exception of SWAP, these techniques and algorithms reduce testing time and inconsistent patient performance when compared with conventional full threshold testing.
Conclusions: Short wavelength automated perimetry detected visual field loss earlier than standard threshold automated perimetry, with a sensitivity and specificity of about 88% and 92% respectively. However, it is a lengthy, demanding test, is sensitive to media opacities, and has a greater magnitude of long-term fluctuation compared with standard threshold automated perimetry, which make it difficult to assess disease progression accurately. When compared to standard threshold automated perimetry, FDT perimetry showed sensitivity and specificity greater than 97% for detecting moderate and advanced glaucoma, and sensitivity of 85% and specificity of 90% for early glaucoma. As FDT perimetry has a short testing time and is resistant to blur and pupil size, it may be a useful screening tool. In a longitudinal study, high-pass resolution perimetry was more effective than standard threshold automated perimetry in monitoring progressive glaucomatous loss, detecting progression at a median of 12 months earlier in 54% of patients studied. Motion automated perimetry demonstrated usefulness in detecting early glaucomatous visual loss in a longitudinal study. Studies on SITA demonstrated greater sensitivity and reproducibility and less intertest variability when compared to standard full threshold testing and a 50% reduction in testing times. A study comparing standard full threshold, SITA, and SITA fast found a sensitivity of 95% for the first two techniques and 93% for SITA fast. Long-term follow-up studies are needed to assess the ability of these techniques to detect progression of glaucoma over time.
Similar articles
-
Comparison of standard automated perimetry, frequency-doubling technology perimetry, and short-wavelength automated perimetry for detection of glaucoma.Invest Ophthalmol Vis Sci. 2011 Sep 21;52(10):7325-31. doi: 10.1167/iovs.11-7795. Invest Ophthalmol Vis Sci. 2011. PMID: 21810975
-
Assessment of visual function in glaucoma: a report by the American Academy of Ophthalmology.Ophthalmology. 2011 May;118(5):986-1002. doi: 10.1016/j.ophtha.2011.03.019. Ophthalmology. 2011. PMID: 21539982
-
Short wavelength automated perimetry, frequency doubling technology perimetry, and pattern electroretinography for prediction of progressive glaucomatous standard visual field defects.Ophthalmology. 2002 May;109(5):1009-17. doi: 10.1016/s0161-6420(02)01015-1. Ophthalmology. 2002. PMID: 11986111
-
Recent developments in automated perimetry in glaucoma diagnosis and management.Curr Opin Ophthalmol. 2002 Apr;13(2):77-84. doi: 10.1097/00055735-200204000-00004. Curr Opin Ophthalmol. 2002. PMID: 11880719 Review.
-
Visual field testing in glaucoma using the Swedish Interactive Thresholding Algorithm (SITA).Surv Ophthalmol. 2025 Jan-Feb;70(1):141-152. doi: 10.1016/j.survophthal.2024.09.005. Epub 2024 Sep 29. Surv Ophthalmol. 2025. PMID: 39349186 Review.
Cited by
-
Influence of pupil size and other test variables on visual function assessment using visual evoked potentials in normal subjects.Doc Ophthalmol. 2010 Aug;121(1):1-7. doi: 10.1007/s10633-010-9222-5. Epub 2010 Feb 10. Doc Ophthalmol. 2010. PMID: 20145988 Free PMC article.
-
Review of Longitudinal Glaucoma Progression: 5 Years after the Shaffer Lecture.Ophthalmol Glaucoma. 2020 Mar-Apr;3(2):158-166. doi: 10.1016/j.ogla.2019.11.012. Epub 2019 Dec 2. Ophthalmol Glaucoma. 2020. PMID: 32373782 Free PMC article.
-
Specvis: Free and open-source software for visual field examination.PLoS One. 2017 Oct 13;12(10):e0186224. doi: 10.1371/journal.pone.0186224. eCollection 2017. PLoS One. 2017. PMID: 29028825 Free PMC article.
-
Ganglion Cell Complex Analysis in Glaucoma Patients: What Can It Tell Us?Eye Brain. 2020 Jan 31;12:33-44. doi: 10.2147/EB.S226319. eCollection 2020. Eye Brain. 2020. PMID: 32099501 Free PMC article. Review.
-
Teleglaucoma: ready to go?Br J Ophthalmol. 2014 Dec;98(12):1605-11. doi: 10.1136/bjophthalmol-2013-304133. Epub 2014 Apr 10. Br J Ophthalmol. 2014. PMID: 24723617 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials