Conventional measurements of GFR using 51Cr-EDTA overestimate true renal clearance by 10 percent
- PMID: 12483403
- DOI: 10.1007/s00259-002-1007-y
Conventional measurements of GFR using 51Cr-EDTA overestimate true renal clearance by 10 percent
Abstract
It is widely believed that measurement of the area under the plasma clearance curve (AUC) following a single intravenous injection of chromium-51 labelled ethylene diamine tetra-acetic acid ((51)Cr-EDTA) is a gold standard method for determining glomerular filtration rate (GFR). However, there are reports that (51)Cr-EDTA may have a significant extrarenal clearance. The aim of this study was to identify the non-renal component of (51)Cr-EDTA plasma clearance contributing to the AUC measurement of GFR. Seventy healthy postmenopausal women (mean age 60 years, range 45-79 years) were injected with 3 MBq (51)Cr-EDTA and 0.25 MBq iodine-125 labelled human serum albumin and 11 blood samples taken between 0 and 4 h through an indwelling venous cannula. For the first 21 subjects, two complete urine collections were made 0-2 h and 2-4 h after injection, and for the final 49 patients, four 1-h urine collections were made. The mean (51)Cr-EDTA total plasma clearance was 84 ml/min (range 50-132 ml/min). The mean ratio (SEM) of urine to total clearance determined from the cumulative 1-, 2-, 3- and 4-h data was 0.903 (0.018), 0.891 (0.013), 0.898 (0.011) and 0.899 (0.010) respectively and remained constant despite the mean urine concentration decreasing from 122% to 15%/litre during this period. A least squares fit to data from the 238 individual urine collections was used to determine the fraction of the total plasma clearance attributable to renal clearance, alpha(0), and the residual urine volume, delta V. The results were alpha(0)=0.910 (95% CI: 0.889-0.932) and delta V=14 ml (95% CI: -4 to +34 ml). The overestimation of the true renal clearance of (51)Cr-EDTA by the AUC method is believed to be due to the failure of the plasma clearance curve to reach the true terminal exponential by 2 h after injection as usually assumed. As a result, conventional measurements of GFR using (51)Cr-EDTA overestimate the true renal clearance of tracer by approximately 10%.
Comment in
-
Overestimation of true renal clearance by conventional measurements of GFR using 51Cr-EDTA.Eur J Nucl Med Mol Imaging. 2003 Jun;30(6):934; author reply 935. doi: 10.1007/s00259-003-1192-3. Epub 2003 Apr 23. Eur J Nucl Med Mol Imaging. 2003. PMID: 12709833 No abstract available.
Similar articles
-
Overestimation of true renal clearance by conventional measurements of GFR using 51Cr-EDTA.Eur J Nucl Med Mol Imaging. 2003 Jun;30(6):934; author reply 935. doi: 10.1007/s00259-003-1192-3. Epub 2003 Apr 23. Eur J Nucl Med Mol Imaging. 2003. PMID: 12709833 No abstract available.
-
Clearance of iohexol, chromium-51-ethylenediaminetetraacetic acid, and creatinine for determining the glomerular filtration rate in pigs with normal renal function: comparison of different clearance techniques.Acad Radiol. 1996 Aug;3(8):651-9. doi: 10.1016/s1076-6332(96)80191-7. Acad Radiol. 1996. PMID: 8796729
-
Chromium-51-EDTA clearance in adults with a single-plasma sample.J Nucl Med. 1998 Dec;39(12):2131-7. J Nucl Med. 1998. PMID: 9867156
-
Measurement of Glomerular Filtration Rate.Semin Nucl Med. 2022 Jul;52(4):453-466. doi: 10.1053/j.semnuclmed.2021.12.005. Epub 2022 Jan 19. Semin Nucl Med. 2022. PMID: 35063168 Review.
-
How to assess glomerular function and damage in humans.J Hypertens. 1999 Mar;17(3):309-17. doi: 10.1097/00004872-199917030-00002. J Hypertens. 1999. PMID: 10100067 Review.
Cited by
-
Validation of a continuous infusion of low dose Iohexol to measure glomerular filtration rate: randomised clinical trial.J Transl Med. 2015 Feb 12;13:58. doi: 10.1186/s12967-015-0414-3. J Transl Med. 2015. PMID: 25885409 Free PMC article. Clinical Trial.
-
Analysis of reactive aldehydes in urine and plasma of type-2 diabetes mellitus patients through liquid chromatography-mass spectrometry: Reactive aldehydes as potential markers of diabetic nephropathy.Front Nutr. 2023 Jan 16;9:997015. doi: 10.3389/fnut.2022.997015. eCollection 2022. Front Nutr. 2023. PMID: 36726822 Free PMC article.
-
Validation of Tikhonov adaptively regularized gamma variate fitting with 24-h plasma clearance in cirrhotic patients with ascites.Eur J Nucl Med Mol Imaging. 2011 Dec;38(12):2247-56. doi: 10.1007/s00259-011-1887-9. Epub 2011 Sep 1. Eur J Nucl Med Mol Imaging. 2011. PMID: 21881927 Free PMC article.
-
Accuracy of iohexol plasma clearance for GFR-determination: a comparison between single and dual sampling.BMC Nephrol. 2018 Jul 11;19(1):174. doi: 10.1186/s12882-018-0965-7. BMC Nephrol. 2018. PMID: 29996810 Free PMC article.
-
Tikhonov adaptively regularized gamma variate fitting to assess plasma clearance of inert renal markers.J Pharmacokinet Pharmacodyn. 2010 Oct;37(5):435-74. doi: 10.1007/s10928-010-9167-z. Epub 2010 Sep 24. J Pharmacokinet Pharmacodyn. 2010. PMID: 20865304 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials