Clinical validation of simultaneous dual-isotope myocardial scintigraphy
- PMID: 12483406
- DOI: 10.1007/s00259-002-0995-y
Clinical validation of simultaneous dual-isotope myocardial scintigraphy
Abstract
Simultaneous dual-isotope (rest thallium-201/stress technetium-99m sestamibi) myocardial single-photon emission tomography (SPET) would be an ideal procedure; however, (99m)Tc cross-talk on the (201)Tl window hampers its routine use. Photon energy recovery (PER) is a spectral deconvolution technique validated for scatter and cross-talk removal in phantom studies and a limited series of patients. In this study we aimed to validate the technique in 295 patients within a context of clinical routine practice. Conventional separate rest (201)Tl myocardial SPET data sets were visually compared with simultaneous dual-isotope data sets corrected by PER. Conventional separate rest (201)Tl data sets were identical to dual PER-corrected (201)Tl data sets in 173 (58.6%) patients. As dual PER (201)Tl data sets are corrected for (99m)Tc cross-talk but also for (201)Tl scatter, they were compared with separate rest (201)Tl data sets corrected by PER in the 122 discordant patients. No difference was found in 77 (26.1%) patients. In 26 (8.8%) patients, the difference consisted in the presence of a defect on dual PER (201)Tl data sets only, mirroring an ischaemic defect on (99m)Tc-sestamibi data sets. This difference can be attributed to the influence of stress on the kinetics of (201)Tl injected at rest. In the remaining 19 (6.4%) patients, the difference between separate and simultaneous PER-corrected data sets was scored as mild in 11 and moderate in eight patients and seemed to be related to multiple methodological factors. It is concluded that PER correctly removes (99m)Tc cross-talk. With the addition of an appropriate attenuation correction, the PER technique may allow the routine use of simultaneous dual-isotope myocardial scintigraphy in the near future.
Similar articles
-
Preliminary clinical results of photon energy recovery in simultaneous rest Tl-201/stress Tc-99m sestamibi myocardial SPECT.J Nucl Cardiol. 2001 Mar-Apr;8(2):144-51. doi: 10.1067/mnc.2001.111799. J Nucl Cardiol. 2001. PMID: 11295691
-
The value and throughput of rest Thallium-201/stress Technetium -99m sestamibi dual-isotope myocardial SPECT.Anadolu Kardiyol Derg. 2004 Jun;4(2):161-8. Anadolu Kardiyol Derg. 2004. PMID: 15165953 Review.
-
Enhanced cross-talk correction technique for simultaneous dual-isotope imaging: a TL-201/Tc-99m myocardial perfusion SPECT dog study.Med Phys. 1997 Dec;24(12):1914-23. doi: 10.1118/1.598105. Med Phys. 1997. PMID: 9434974
-
Separate acquisition rest thallium-201/stress technetium-99m sestamibi dual-isotope myocardial perfusion single-photon emission computed tomography: a clinical validation study.J Am Coll Cardiol. 1993 Nov 1;22(5):1455-64. doi: 10.1016/0735-1097(93)90557-h. J Am Coll Cardiol. 1993. PMID: 8227805 Clinical Trial.
-
Dual-isotope myocardial perfusion SPECT with rest thallium-201 and stress Tc-99m sestamibi.Cardiol Clin. 1994 May;12(2):261-70. Cardiol Clin. 1994. PMID: 8033176 Review.
Cited by
-
Validation of early image acquisitions following Tc-99 m sestamibi injection using a semiconductors camera of cadmium-zinc-telluride.J Nucl Cardiol. 2017 Aug;24(4):1149-1156. doi: 10.1007/s12350-016-0499-y. Epub 2016 Apr 20. J Nucl Cardiol. 2017. PMID: 27098337
-
A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential.Eur J Nucl Med Mol Imaging. 2010 Oct;37(10):1887-902. doi: 10.1007/s00259-010-1488-z. Epub 2010 Jun 29. Eur J Nucl Med Mol Imaging. 2010. PMID: 20585775 Free PMC article.
-
Optimisation of simultaneous tl-201/tc-99m dual isotope reconstruction with monte-carlo-based scatter correction.Int J Mol Imaging. 2012;2012:695632. doi: 10.1155/2012/695632. Epub 2012 Nov 19. Int J Mol Imaging. 2012. PMID: 23213515 Free PMC article.
-
Multiplexed imaging in cancer diagnosis: applications and future advances.Lancet Oncol. 2010 Jun;11(6):589-95. doi: 10.1016/S1470-2045(10)70009-7. Epub 2010 Mar 24. Lancet Oncol. 2010. PMID: 20338808 Free PMC article. Review.
-
Impact of photon energy recovery on the assessment of left ventricular volume using myocardial perfusion SPECT.J Nucl Cardiol. 2004 May-Jun;11(3):312-7. doi: 10.1016/j.nuclcard.2004.03.001. J Nucl Cardiol. 2004. PMID: 15173778 Clinical Trial.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Research Materials